background image

What

 

the

 

server

 

offers

 

The

 

server

 

uses

 

the

 

following

 

features

 

and

 

technologies:

 

v

   

Active

 

PCI

 

(hot-plug)

 

adapter

 

capabilities

 

The

 

server

 

has

 

one

 

hot-plug

 

slot

 

for

 

a

 

peripheral

 

component

 

interconnect

 

(PCI)

 

adapter.

 

With

 

operating

 

system

 

support,

 

you

 

can

 

replace

 

a

 

failing

 

hot-plug

 

a

 

PCI

 

adapter

 

without

 

turning

 

off

 

the

 

server.

 

If

 

the

 

operating

 

system

 

and

 

the

 

adapter

 

support

 

the

 

hot-add

 

feature,

 

you

 

can

 

also

 

add

 

a

 

PCI

 

adapter

 

in

 

this

 

slot

 

without

 

turning

 

off

 

the

 

server.

 

v

   

Active

 

PCI

 

Express

 

X4

 

adapter

 

capabilities

 

The

 

server

 

has

 

two

 

slots

 

for

 

PCI

 

Express

 

X4

 

adapters.These

 

slots

 

will

 

accept

 

X8

 

adapters,

 

however

 

they

 

will

 

operate

 

as

 

a

 

X4

 

adapter.

 

v

   

Baseboard

 

management

 

controller

 

The

 

baseboard

 

management

 

controller

 

provides

 

environmental

 

monitoring

 

for

 

the

 

server.

 

If

 

an

 

environmental

 

condition

 

exceeds

 

a

 

threshold

 

or

 

if

 

a

 

system

 

component

 

fails,

 

the

 

baseboard

 

management

 

controller

 

lights

 

LEDs

 

to

 

help

 

you

 

diagnose

 

the

 

problem.

 

Critical

 

errors

 

are

 

also

 

included

 

in

 

the

 

error

 

log.

 

Note:

 

The

 

baseboard

 

management

 

controller

 

is

 

also

 

known

 

as

 

the

 

service

 

processor.

 

v

   

IBM

 

Director

 

IBM

 

Director

 

is

 

a

 

workgroup-hardware-management

 

tool

 

that

 

you

 

can

 

use

 

to

 

centrally

 

manage

 

xSeries

 

servers.

 

For

 

more

 

information,

 

see

 

the

 

IBM

 

Director

 

documentation

 

on

 

the

 

IBM

 

Director

 

CD.

 

v

   

Memory

 

mirroring

 

Memory

 

mirroring

 

improves

 

the

 

reliability

 

of

 

memory

 

by

 

writing

 

information

 

to

 

the

 

main

 

memory

 

and

 

redundant

 

locations

 

in

 

a

 

mirrored

 

pair

 

of

 

DIMMs.

 

For

 

more

 

information,

 

see

 

“Memory

 

mirroring”

 

on

 

page

 

7.

 

v

   

Online-spare

 

memory

 

Online-spare

 

memory

 

disables

 

failed

 

memory

 

from

 

the

 

system

 

configuration

 

and

 

activates

 

an

 

online-spare

 

memory

 

pair

 

of

 

DIMMs

 

to

 

replace

 

the

 

failed

 

pair.

 

For

 

more

 

information,

 

see

 

“Online-spare

 

memory”

 

on

 

page

 

7.

 

v

   

Large

 

system-memory

 

capacity

 

The

 

server

 

supports

 

up

 

to

 

16

 

GB

 

of

 

system

 

memory.

 

The

 

memory

 

controller

 

supports

 

error

 

correcting

 

code

 

(ECC)

 

for

 

up

 

to

 

eight

 

single-sided

 

industry-standard

 

PC3200,

 

400

 

megahertz

 

(MHz),

 

1.8

 

V,

 

240-pin,

 

registered,

 

double-data-rate

 

(DDR)

 

II,

 

synchronous

 

dynamic

 

random

 

access

 

memory

 

(SDRAM)

 

dual

 

inline

 

memory

 

modules

 

(DIMMs).

 

The

 

memory

 

controller

 

also

 

provides

 

Chipkill

 

Memory

 

protection

 

if

 

the

 

DIMMs

 

are

 

all

 

type

 

x4

 

and

 

larger

 

than

 

128

 

MB.

 

Chipkill

 

Memory

 

protection

 

is

 

a

 

technology

 

that

 

protects

 

the

 

server

 

from

 

a

 

single

 

chip

 

failure

 

on

 

a

 

DIMM.

 

v

   

IBM

 

ServerGuide

 

Setup

 

and

 

Installation

 

CD

 

The

 

ServerGuide

 

Setup

 

and

 

Installation

 

CD

 

that

 

comes

 

with

 

the

 

server

 

provides

 

programs

 

to

 

help

 

you

 

set

 

up

 

the

 

server

 

and

 

install

 

a

 

32-bit

 

Windows

®

 

operating

 

system.

 

The

 

ServerGuide

 

program

 

detects

 

installed

 

hardware

 

options

 

and

 

provides

 

the

 

correct

 

configuration

 

programs

 

and

 

device

 

drivers.

 

For

 

more

 

information

 

about

 

the

 

ServerGuide

 

Setup

 

and

 

Installation

 

CD,

 

see

 

“Using

 

the

 

ServerGuide

 

Setup

 

and

 

Installation

 

CD”

 

on

 

page

 

22.

   

4

 

IBM

 

xSeries

 

236

 

Type

 

8841:

 

User’s

 

Guide

Содержание eServer xSeries 236

Страница 1: ...IBM xSeries 236 Type 8841 User s Guide ERserver...

Страница 2: ......

Страница 3: ...IBM xSeries 236 Type 8841 User s Guide ERserver...

Страница 4: ...ral information in Appendix B Notices on page 43 First Edition October 2004 Copyright International Business Machines Corporation 2004 All rights reserved US Government Users Restricted Rights Use dup...

Страница 5: ...view 23 Typical operating system installation 24 Installing your operating system without ServerGuide 24 Using the SCSISelect Utility program for Adaptec HostRAID configuration 24 Enabling the SCSI Ho...

Страница 6: ...stralia and New Zealand Class A statement 47 United Kingdom telecommunications safety requirement 47 European Union EMC Directive conformance statement 47 Taiwanese Class A warning statement 47 Chines...

Страница 7: ...alleert eerst de veiligheidsvoorschriften Ennen kuin asennat t m n tuotteen lue turvaohjeet kohdasta Safety Information Avant d installer ce produit lisez les consignes de s curit Vor der Installation...

Страница 8: ...ated versions of the caution or danger statement in the IBM Safety Information book For example if a caution statement begins with a number 1 translations for that caution statement appear in the IBM...

Страница 9: ...quipment when there is evidence of fire water or structural damage v Disconnect the attached power cords telecommunications systems networks and modems before you open the device covers unless instruc...

Страница 10: ...s Statement 3 CAUTION When laser products such as CD ROMs DVD drives fiber optic devices or transmitters are installed note the following v Do not remove the covers Removing the covers of the laser pr...

Страница 11: ...power control button on the device and the power switch on the power supply do not turn off the electrical current supplied to the device The device also might have more than one power cord To remove...

Страница 12: ...label attached Hazardous voltage current and energy levels are present inside any component that has this label attached There are no serviceable parts inside these components If you suspect a proble...

Страница 13: ...ical assistance on page 41 Related documentation This User s Guide provides general information about the server including information about features how to configure the server and how to get help In...

Страница 14: ...on the IBM xSeries Documentation CD Each statement is numbered for reference to the corresponding statement in the Safety Information document The following types of notices and statements are used in...

Страница 15: ...serial connectors v One parallel connector v Support for one external and one optional external or internal Ultra320 SCSI connector dual channel SCSI controller with RAID capabilities v Three Univers...

Страница 16: ...oring improves the reliability of memory by writing information to the main memory and redundant locations in a mirrored pair of DIMMs For more information see Memory mirroring on page 7 v Online spar...

Страница 17: ...user intervention v Redundant power and cooling capabilities The server supports up to two 670 watt hot swap power supplies If the server comes with only one power supply you can install an additiona...

Страница 18: ...agnostics LED panels v Integrated service processor subsystem for remote system management v Key lock support for physical security v Availability of microcode and diagnostic levels v Parity checking...

Страница 19: ...memory DIMM pair to replace the failed pair Before you can enable this feature you must install one additional pair of DIMMs The online spare memory DIMM pair must be the same speed and type and the s...

Страница 20: ...v Ease of use training and setup IBM Director also provides an extensible platform that supports advanced server tools that are designed to reduce the total cost of managing and supporting networked s...

Страница 21: ...reen Diskette drive activity LED Diskette eject button USB 3 connector Hard disk drive status LED amber Reset button Power control button Power control button shield if installed Cover release latch M...

Страница 22: ...se IBM Director to light this LED remotely v Ethernet transmit receive activity LED Tx Rx 1 or Tx Rx 2 When these two green LEDs are lit they indicate that there is activity between the server and the...

Страница 23: ...CD eject button Press this button to release a CD from the CD ROM drive Chapter 1 Introducing the IBM xSeries 236 Type 8841 server 11...

Страница 24: ...lel device to this connector Serial 1 connector Connect a 9 pin serial device to this connector USB 1 connector Connect a USB device to this connector Ethernet link 1 status LED This LED is on the Eth...

Страница 25: ...shut down however the server can respond to requests from the service processor also called the baseboard management controller such as a remote request to turn on the server The power on LED flashes...

Страница 26: ...can be turned off in any of the following ways v You can turn off the server from the operating system if your operating system supports this feature After an orderly shutdown of the operating system...

Страница 27: ...v You can turn off the server through a request from the service processor Chapter 1 Introducing the IBM xSeries 236 Type 8841 server 15...

Страница 28: ...16 IBM xSeries 236 Type 8841 User s Guide...

Страница 29: ...ServeRAID Manager on page 26 v SCSISelect Utility program for Adaptec HostRAID configuration Use the SCSI HostRAID feature of the SCSISelect Utility program to configure the SCSI controller with inte...

Страница 30: ...to view information about your server When you make changes through other options in the Configuration Setup Utility program some of those changes are reflected in the system information you cannot c...

Страница 31: ...more information Remote Control Password Select this choice to set or change a remote control password See Remote control password on page 22 for more information This choice is on the Configuration...

Страница 32: ...ices and to configure the master latency timer value for the server Integrated System Management Processor Settings Select this choice to enable or disable the Reboot on System NMI option on the menu...

Страница 33: ...an administrator password The System Security choice is on the full Configuration Setup menu only If you set only a power on password you must type the power on password to complete the system startu...

Страница 34: ...cess to the full Configuration Setup Utility menu You can use any combination of up to seven characters A Z a z and 0 9 for the password The Administrator Password choice is on the Configuration Setup...

Страница 35: ...with an enabled startable bootable CD ROM drive In addition to the ServerGuide Setup and Installation CD you must have your operating system CD to install your operating system The ServerGuide progra...

Страница 36: ...e ServerGuide program prompts you to insert your operating system CD and restart the server At this point the installation program for the operating system takes control to complete the installation I...

Страница 37: ...n method described in the instructions that come with that adapter to view or change SCSI settings for attached devices See the documentation on the ServeRAID 7e Adaptec HostRAID Support CD for additi...

Страница 38: ...ngs erasing all data from the disk v View the RAID configuration and associated devices v Monitor operation of the RAID controllers The ServeRAID Manager program operates in two ways v Startable CD mo...

Страница 39: ...roller lights LEDs to help you diagnose the problem and also records the error in the System Event Error log The baseboard management controller also provides the following remote server management ca...

Страница 40: ...Emulation ANSI v Remote Console Keyboard Emulation ANSI v Remote Console Active After Boot Enabled v Remote Console Flow Control Hardware d Press Esc twice to exit the Remote Console Redirection and D...

Страница 41: ...respawn sbin agetty h ttyS0 19200 vt102 2 Add the following line at the bottom of the etc securetty file to enable a user to log in as the root user through the SOL console ttyS1 LILO configuration I...

Страница 42: ...all boot boot b message boot message linear image boot vmlinuz 2 4 9 e 12smp label linux initrd boot initrd 2 4 9 e 12smp img read only root dev hda6 image boot vmlinuz 2 4 9 e 12 label linux up initr...

Страница 43: ...Linux operating system starts a LILO boot prompt is displayed instead of the graphical user interface Press Tab at this prompt to install all of the boot options that are listed To load the operating...

Страница 44: ...by anaconda Note that you do not have to rerun grub after making changes to this file NOTICE You have a boot partition This means that all kernel and initrd paths are relative to boot eg root hd0 0 ke...

Страница 45: ...itrd initrd 2 4 9 e 12 img You must restart the Linux operating system after completing these procedures for the changes to take effect and to enable SOL SUSE SLES 8 0 configuration Note This procedur...

Страница 46: ...r white blue black light gray default 0 timeout 8 title linux kernel hd0 1 boot vmlinuz root dev hda2 acpi oldboot vga 791 1 initrd hd0 1 boot initrd title floppy root chainloader 1 title failsafe ker...

Страница 47: ...ompt then press Enter to display the current boot options for your server b In the Boot Entries section locate the boot entry ID for the section with an OS friendly name of Windows Server 2003 Standar...

Страница 48: ...0 disk 0 rdisk 0 partition 1 WINDOWS OS Load Options fastdetect redirect You must restart the Windows 2003 operating system after completing this procedure for the changes to take effect and to enabl...

Страница 49: ...rver running a Linux operating system You must be logged in as a root user to perform these procedures 1 Go to http www ibm com pc support and download the utility program and create the OSA BMC Manag...

Страница 50: ...tructions on the screen Using the baseboard management controller firmware update utility program Use the baseboard management controller firmware update utility program to download a baseboard manage...

Страница 51: ...use SOL to remotely view and change the server BIOS settings At a command prompt type telenet localhost 623 to access the SOL network Type help at the smbridge prompt for more information Use the fol...

Страница 52: ...40 IBM xSeries 236 Type 8841 User s Guide...

Страница 53: ...nce by following the troubleshooting procedures that IBM provides in the online help or in the publications that are provided with your system and software The information that comes with your system...

Страница 54: ...information about which products are supported by Support Line in your country or region go to http www ibm com services sl products For more information about Support Line and other IBM services go...

Страница 55: ...TY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF NON INFRINGEMENT MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Some states do not allow disclaimer...

Страница 56: ...Corporation in the United States other countries or both UNIX is a registered trademark of The Open Group in the United States and other countries Java and all Java based trademarks and logos are trad...

Страница 57: ...ilable and may not include user manuals or all program functionality Product recycling and disposal This unit contains materials such as circuit boards cables electromagnetic compatibility gaskets and...

Страница 58: ...instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be requ...

Страница 59: ...EC on the approximation of the laws of the Member States relating to electromagnetic compatibility IBM cannot accept responsibility for any failure to satisfy the protection requirements resulting fro...

Страница 60: ...llel blade grounding type attachment plug rated 15 amperes 125 volts For units intended to be operated at 230 volts U S use Use a UL listed and CSA certified cord set consisting of a minimum 18 AWG Ty...

Страница 61: ...tan Ukraine Upper Volta Uzbekistan Vanuatu Vietnam Wallis and Futuna Yugoslavia Federal Republic of Zaire 13F9997 Denmark 14F0015 Bangladesh Lesotho Macao Maldives Namibia Nepal Pakistan Samoa South A...

Страница 62: ...Caicos Islands Canada Cayman Islands Colombia Costa Rica Cuba Dominican Republic Ecuador El Salvador Guam Guatemala Haiti Honduras Jamaica Mexico Micronesia Federal States of Netherlands Antilles Nic...

Страница 63: ...n 10 drives 5 E electrical input 3 electronic emission Class A notice 46 enabling the SCSI HostRAID feature 25 environment 3 Ethernet 5 Ethernet activity LED 13 Ethernet connectors 1 and 2 12 Ethernet...

Страница 64: ...lity using to configure the SCSI controller 24 serial 1 connector 12 serial 2 connector 12 serial over LAN commands connect 39 identify 39 power 39 reboot 39 sel get 39 serial over LAN continued comma...

Страница 65: ......

Страница 66: ...Part Number 25K9164 Printed in USA 1P P N 25K9164...

Отзывы: