82
IBM xSeries 135: User’s Reference
Diagnostic error message tables
The following tables provide descriptions of the error messages that might appear
when you run the diagnostic programs.
Table 14. Diagnostic error messages
Code
Function
Result
Text message
Action
001
Core system
Failed
Processor board, ECC Test
Call for service.
System board
005
Video port
Processor and system boards
011
Serial port
Integrated serial port
014
Parallel port
Integrated parallel port
015
USB interface
Aborted
Can NOT test USB interface while it is in use.
Note:
If you have a USB keyboard or mouse
attached, you cannot run the diagnostic
program for the USB interface.
1. Turn off the server.
2. Replace the USB
keyboard and
mouse with a
standard keyboard
and mouse.
3. Turn on the server.
4. Run the diagnostic
test again.
Failed
System board
Call for service.
020
PCI interface
Failed
System board
Call for service.
030
SCSI interface
Failed
SCSI adapter in slot n failed register/counter/ power
test
(where n is the slot number of the failing adapter)
Refer to the information
provided with the
adapter for instructions.
If the problem persists,
call for service.
SCSI controller on system board failed
register/counter/power test
Call for service.
075
Power supply
Failed
Voltage sensed by the system is out of range
Call for service.
If diagnostic error messages appear that are not listed in the following tables,
make sure that your server has the latest levels of BIOS and diagnostics
microcode installed.
Important