Completing the Installation
__ 1.
Power on the PC or workstation that is your system unit console.
__ 2.
Is your system unit a 270/810 or 820/825?
__
270 or 810
: Continue with the next step.
__
820, 825, 830, 840, SB2, SB3, 870 or 890
: Go to step 5.
__ 3.
Look at the Function/Data display on the control panel.
__ 4.
Does
01 B M V=S
appear in the Function/Data display?
__
Yes
: Go to step 7 on page 8.
__
No
: Do the following:
__ a.
Press the Increment/Decrement push button until
02
appears
in the Function/Data display.
__ b.
Press the Enter push button on the control panel.
__ c.
Press the Increment/Decrement push button until
B
appears in
the Function/Data display.
__ d.
Press the Enter push button on the control panel.
__ e.
Press the Increment/Decrement push button until
M
appears in
the Function/Data display.
__ f.
Press the Enter push button on the control panel.
__ g.
Press the Increment/Decrement push button until
S
appears in
the Function/Data display.
__ h.
Press the Enter push button on the control panel.
__ i.
Press the Increment/Decrement push button until
01
appears
in the Function/Data display.
__ j.
Press the Enter push button on the control panel.
01 B M S
should appear in the Function/Data display. If it does
not, repeat steps 4a through 4i.
__ k.
Go to step 7 on page 8.
__ 5.
Look at the Function/Data display on the control panel.
__ 6.
Does
01 B V=S
appear in the Function/Data display and is the manual
mode indicator (a small hand) illuminated?
__
Yes
: Continue with the next step.
__
No
: Do the following:
__ a.
Press the Mode Select button until the Manual mode indicator
(a small hand) is illuminated.
__ b.
Press the Increment/Decrement push button until
02
appears
in the Function/Data display.
__ c.
Press the Enter push button on the control panel.
__ d.
Press the Increment/Decrement push button until
B
appears in
the Function/Data display.
__ e.
Press the Enter push button on the control panel.
__ f.
Press the Increment/Decrement push button until
S
appears in
the Function/Data display
__ g.
Press the Enter push button on the control panel.
__ h.
Press the Increment/Decrement push button until
01
appears
in the Function/Data display.
__ i.
Press the Enter push button on the control panel.
Upgrade Operations Console to twinaxial console
7
Содержание eServer iSeries 8 Series
Страница 2: ......
Страница 18: ...14 Upgrading the System Unit from Operations Console to Twinaxial Console 5540 V5R2...
Страница 23: ...v Additional disk unit controllers are not allowed in SB2 and SB3 system units Configuration tables 19...
Страница 24: ...20 Upgrading the System Unit from Operations Console to Twinaxial Console 5540 V5R2...
Страница 27: ......
Страница 28: ...Printed in U S A...