background image

Install

 

a

 

Model

 

270,

 

800,

 

or

 

810

 

in

 

a

 

rack

 

This

 

feature

 

is

 

customer

 

installable.

 

However,

 

the

 

installation

 

of

 

this

 

feature

 

is

 

intended

 

for

 

an

 

experienced

 

user

 

who

 

understands

 

industry

 

terminology

 

with

 

system

 

experience.

 

Also,

 

as

 

you

 

follow

 

the

 

instructions,

 

after

 

removing

 

the

 

devices,

 

three

 

people

 

are

 

needed

 

to

 

safely

 

lift

 

the

 

unit

 

onto

 

the

 

rack.

 

When

 

you

 

use

 

these

 

instructions,

 

you

 

will

 

perform

 

some

 

or

 

all

 

of

 

the

 

following

 

tasks:

 

v

   

Perform

 

prerequisite

 

tasks.

 

v

   

Remove

 

the

 

system

 

unit

 

covers.

 

v

   

Install

 

new

 

hardware.

 

v

   

Install

 

covers.

 

v

   

IPL

 

your

 

operating

 

system.

 

v

   

Verify

 

your

 

new

 

hardware

 

configuration.

You

 

may

 

need

 

to

 

allow

 

additional

 

time

 

to

 

complete

 

your

 

jobs,

 

back

 

up

 

your

 

system,

 

perform

 

an

 

initial

 

program

 

load

 

(IPL)

 

of

 

your

 

system,

 

and

 

verify

 

your

 

hardware

 

configuration.

 

You

 

can

 

choose

 

to

 

perform

 

these

 

tasks

 

yourself

 

or

 

contact

 

IBM(R)

 

or

 

an

 

authorized

 

service

 

provider

 

to

 

make

 

arrangements

 

for

 

them

 

to

 

perform

 

the

 

tasks

 

for

 

a

 

fee.

 

Should

 

you

 

encounter

 

difficulties

 

when

 

performing

 

a

 

task,

 

contact

 

your

 

authorized

 

dealer

 

or

 

service

 

provider.

 

Rack

 

safety

 

instructions

 

CAUTION:

  

v

   

Do

 

not

 

install

 

a

 

unit

 

in

 

a

 

rack

 

where

 

the

 

internal

 

rack

 

ambient

 

temperatures

 

will

 

exceed

 

40

 

degrees

 

C.

 

v

   

Do

 

not

 

install

 

a

 

unit

 

in

 

a

 

rack

 

where

 

the

 

air

 

flow

 

is

 

compromised.

 

Any

 

side,

 

front

 

or

 

back

 

of

 

a

 

unit

 

used

 

for

 

air

 

flow

 

through

 

the

 

unit

 

must

 

not

 

be

 

in

 

direct

 

contact

 

with

 

the

 

rack.

 

v

   

Care

 

should

 

be

 

taken

 

to

 

ensure

 

that

 

a

 

hazardous

 

condition

 

is

 

not

 

created

 

due

 

to

 

uneven

 

mechanical

 

loading

 

when

 

installing

 

a

 

unit

 

in

 

a

 

rack.

 

If

 

the

 

rack

 

has

 

a

 

stabilizer

 

it

 

must

 

be

 

firmly

 

attached

 

before

 

uninstalling

 

or

 

removing

 

this

 

unit.

 

v

   

Consideration

 

should

 

be

 

given

 

to

 

the

 

connection

 

of

 

the

 

equipment

 

to

 

the

 

supply

 

circuit

 

so

 

that

 

overloading

 

of

 

the

 

circuits

 

does

 

not

 

compromise

 

the

 

supply

 

wiring

 

or

 

overcurrent

 

protection.

 

To

 

provide

 

the

 

correct

 

power

 

connection

 

to

 

a

 

rack,

 

refer

 

to

 

the

 

rating

 

labels

 

located

 

on

 

the

 

equipment

 

in

 

the

 

rack

 

to

 

determine

 

the

 

total

 

power

 

requirement

 

of

 

the

 

supply

 

circuit.

 

v

   

An

 

electrical

 

outlet

 

that

 

is

 

not

 

correctly

 

wired

 

could

 

place

 

hazardous

 

voltage

 

on

 

the

 

metal

 

parts

 

of

 

the

 

system

 

or

 

the

 

devices

 

that

 

attach

 

to

 

the

 

system.

 

It

 

is

 

the

 

responsibility

 

of

 

the

 

customer

 

to

 

ensure

 

that

 

the

 

outlet

 

is

 

correctly

 

wired

 

and

 

grounded

 

to

 

prevent

 

an

 

electrical

 

shock.

 

v

   

Since

 

the

 

design

 

and

 

configuration

 

of

 

rack

 

enclosures

 

varies,

 

consideration

 

must

 

be

 

given

 

to

 

the

 

placement

 

of

 

IBM

 

units

 

into

 

third

 

party

 

racks

 

and

 

third

 

party

 

units

 

into

 

IBM

 

racks.

 

It

 

is

 

the

 

customer’s

 

responsibility

 

to

 

ensure

 

the

 

unit

 

can

 

be

 

safely

 

mounted

 

in

 

the

 

rack

 

and

 

the

 

rack

 

enclosure

 

adequately

 

provides

 

proper

 

ventilation/cooling,

 

proper

 

stability,

 

and

 

sufficient

 

structural

 

integrity

 

for

 

the

 

unit

 

when

 

installed

 

in

 

the

 

rack.

 

(RSFTC247)

 

CAUTION:

 

These

 

instructions

 

describe

 

how

 

to

 

install

 

a

 

rack

 

stabilizer

 

to

 

the

 

bottom

 

front

 

of

 

each

 

rack

 

to

 

prevent

 

the

 

rack

 

from

 

falling

 

over

 

when

 

you

 

slide

 

or

 

pull

 

out

 

the

 

system

 

units.

 

Do

 

not

 

attempt

 

to

 

slide

 

out

 

or

 

install

 

any

 

system

 

units

 

until

 

the

 

stabilizer

 

is

 

correctly

 

installed.

 

Use

 

caution

 

when

 

moving

 

the

 

rack

 

and

 

its

 

system

 

units.

 

(RSFTC063)

 

©

 

Copyright

 

IBM

 

Corp.

 

2004,

 

2005

 

1

Содержание Eserver i Series

Страница 1: ...iSeries 270 800 and 810 units in a rack installation instructions Version 5 ERserver...

Страница 2: ......

Страница 3: ...iSeries 270 800 and 810 units in a rack installation instructions Version 5 ERserver...

Страница 4: ...product number 5722 SS1 and to all subsequent releases and modifications until otherwise indicated in new editions This version does not run on all reduced instruction set computer RISC models nor do...

Страница 5: ...assemblies Model 270 only 20 Install unit in the rack 22 Install devices that were removed 25 Electrostatic discharge 25 Install disk units 26 Install tape CD ROM and DVD devices 27 Install processor...

Страница 6: ...iv 270 800 810 In Rack Installation Instructions V5R3...

Страница 7: ...uneven mechanical loading when installing a unit in a rack If the rack has a stabilizer it must be firmly attached before uninstalling or removing this unit v Consideration should be given to the con...

Страница 8: ...IBM Rochester Manufacturing Automated Information Line R MAIL at 1 800 300 8751 v In countries outside of the United States Use the following Web site to locate your service and support numbers http w...

Страница 9: ...Unplug any power cords such as printers and displays from electrical outlets __ 8 Unplug the system unit and expansion unit power cords from the electrical outlets Rack installation instructions __ 1...

Страница 10: ...__ 7 Remove all the filler panels to allow access to the inside of the rack enclosure 4 270 800 810 In Rack Installation Instructions V5R3...

Страница 11: ...__ 8 Open the back door Install a Model 270 800 or 810 in a rack 5...

Страница 12: ...__ 9 Plan where you will place the units you are installing in the rack Place the larger and heavier units in the lower part of the rack 6 270 800 810 In Rack Installation Instructions V5R3...

Страница 13: ...with rail assembly B adapter plate C clips and screws D Some extra screws are provided __ 2 Install the adapter plate on the shelf __ a Locate the 10 screws to install the 270 800 or 810 shelf plate _...

Страница 14: ..._ 3 Install four clips on the front of the rack If you are installing the unit in the lower part of the rack place the clips in EIA sections 1 and 2 8 270 800 810 In Rack Installation Instructions V5R...

Страница 15: ...To install in the upper part place the clips in EIA sections 17 and 18 Install a Model 270 800 or 810 in a rack 9...

Страница 16: ...A Guidepins B Clips 10 270 800 810 In Rack Installation Instructions V5R3...

Страница 17: ...e other one in the front of the rack __ 5 Lift the shelf and rail assembly into the rack from the front You need to slant the shelf to fit through the front opening __ 6 Align and insert the guidepins...

Страница 18: ...8 Install two screws on each side of the back frame to secure the shelf assembly __ 9 Open the latches on the shelf A Slide the shelf partially out Install the two screws on each side of the front fr...

Страница 19: ...ll in the correct position __ 10 Slide the shelf into the rack __ 11 Press in the latches to lock the shelf in the rack __ 12 Locate the cable management arm assembly __ 13 Push in the latches to secu...

Страница 20: ...s before lifting the system unit into the rack To safely lift your unit onto the rack shelf use the instructions to remove devices from the unit Place devices that you remove in the electrostatic disc...

Страница 21: ...liner from the copper foil at the end when you unroll the strap 3 Attach the copper foil to an exposed unpainted metal surface on the frame of the system unit electrical ground 4 Place devices that y...

Страница 22: ...2 Remove the disk unit covers Squeeze the latch and pull out __ 3 It is very important to label the disk units and locations as you remove them so they are later installed in the exact same position F...

Страница 23: ...emove the disk unit If the handle is not all the way down the disk unit will not slide out of the system __ 5 Support the bottom of the disk unit assembly as you slide it completely out Do not hold th...

Страница 24: ...ns Remove tape CD ROM or DVD devices __ 1 Disconnect the signal larger connector and power smaller connector cables from the back of the device Access to these connectors is from the side of the syste...

Страница 25: ...e device by sliding it forward and out of the system unit You may need to remove the filler blank above the control panel __ 4 Place the device in a static protective bag Install a Model 270 800 or 81...

Страница 26: ...1 Remove the access cover A Pull out latch B __ 2 Remove the processor card assemblies A and B by doing the following __ a Unlatch the two latches C until the card assembly slightly pops out 20 270 8...

Страница 27: ...at the same time to remove the card assembly from the system unit __ c Put the card assembly in a static protective bag __ 3 Repeat the steps to remove all processor card assemblies Install a Model 27...

Страница 28: ...hat a rack stabilizer is attached to the bottom front of the rack Do not pull out more than one unit at a time The rack can turn over if you pull out more than one unit at a time RSFTC224 __ 2 Install...

Страница 29: ...hed to the shelf the six holes where you will install screws to securely attach the unit to the shelf __ 6 Lift the unit onto the shelf positioning it toward the back of the shelf __ 7 Slide the syste...

Страница 30: ...__ 8 Install the six screws from the bottom of the rack shelf to secure the unit to the shelf 24 270 800 810 In Rack Installation Instructions V5R3...

Страница 31: ...the following instructions to install the devices that were removed Electrostatic discharge Attach the disposable wrist strap to prevent electrostatic discharge from damaging a device View video Attac...

Страница 32: ...rom the copper foil at the end when you unroll the strap 3 Attach the copper foil to an exposed unpainted metal surface on the frame of the unit electrical ground Install disk units __ 1 The disk unit...

Страница 33: ...atch __ 6 Repeat the above steps for each disk unit in your system __ 7 Install the disk unit covers __ 8 Continue with the instructions Install tape CD ROM and DVD devices __ 1 Install the device by...

Страница 34: ...tall the processor card assembly A by doing the following __ a Slide the card assembly into the system unit __ b Push on both card latches at the same time __ c Close the latches when you cannot push...

Страница 35: ...__ 2 Install the access cover A Push in B Install a Model 270 800 or 810 in a rack 29...

Страница 36: ...__ 3 Repeat the steps to install all processor card assemblies 30 270 800 810 In Rack Installation Instructions V5R3...

Страница 37: ...ted retainer screws on the back right side cover view from front __ 2 Install the front cover __ 3 Push in the spring latches on the extended shelf rails and slide the shelf in __ 4 Close the shelf la...

Страница 38: ...32 270 800 810 In Rack Installation Instructions V5R3...

Страница 39: ...nstructions that came with your system unit to finish the set up You may have already completed some of the steps If you installed an existing system unit __ 1 Plug in the power cord for the system un...

Страница 40: ...34 270 800 810 In Rack Installation Instructions V5R3...

Страница 41: ...ot apply to you This information could include technical inaccuracies or typographical errors Changes are periodically made to the information herein these changes will be incorporated in new editions...

Страница 42: ...cific machines indicated IBM makes no representations that it is suitable for any other purpose The drawings and specifications contained herein shall not be reproduced in whole or in part without the...

Страница 43: ...contained therein IBM reserves the right to withdraw the permissions granted herein whenever in its discretion the use of the Publications is detrimental to its interest or as determined by IBM the a...

Страница 44: ...ration is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesir...

Страница 45: ...n Chinese Simplified Chinese Declaration This is a Class A product In a domestic environment this product may cause radio interference in which case the user may need to perform practical action Elect...

Страница 46: ...ion reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures v Reorient or relocate the...

Страница 47: ...tion cards This product has been tested and found to comply with the limits for Class B Information Technology Equipment according to CISPR 22 European Standard EN 55022 The limits for Class B equipme...

Страница 48: ...42 270 800 810 In Rack Installation Instructions V5R3...

Страница 49: ......

Страница 50: ...Printed in USA...

Отзывы: