Hard
disk
drive
problems
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
Chapter
3,
“Parts
listing,
Type
7981
and
1884,”
on
page
53
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Symptom
Action
Not
all
drives
are
recognized
by
the
Fixed
Disk
or
SAS
Attached
Disk
diagnostic
test.
Remove
the
drive
that
is
indicated
by
the
diagnostic
tests;
then,
run
the
Fixed
Disk
or
SAS
Attached
Disk
diagnostic
test
again.
If
the
remaining
drives
are
recognized,
replace
the
drive
that
you
removed
with
a
new
one.
The
blade
server
stops
responding
during
the
Fixed
Disk
or
SAS
Attached
Disk
diagnostic
test.
Remove
the
hard
disk
drive
that
was
being
tested
when
the
blade
server
stopped
responding,
and
run
the
diagnostic
test
again.
If
the
Fixed
Disk
or
SAS
Attached
Disk
diagnostic
test
runs
successfully,
replace
the
drive
that
you
removed
with
a
new
one.
A
hard
disk
drive
passes
the
Fixed
Disk
or
SAS
Attached
Disk
diagnostics
test,
but
the
problem
remains.
Run
the
SAS
Fixed
Disk
or
SAS
Attached
Disk
diagnostic
test
again.
If
the
diagnostics
continue
to
pass
but
the
drive
continues
to
have
a
problem,
replace
the
drive
with
a
new
one.
Intermittent
problems
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
Chapter
3,
“Parts
listing,
Type
7981
and
1884,”
on
page
53
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Symptom
Action
A
problem
occurs
only
occasionally
and
is
difficult
to
diagnose.
1.
Make
sure
that:
v
When
the
blade
server
is
turned
on,
air
is
flowing
from
the
rear
of
the
blade
server
at
the
blower
grille.
If
there
is
no
airflow,
the
blower
is
not
working.
This
causes
the
blade
server
to
overheat
and
shut
down.
v
The
SAS
hard
disk
drives
are
configured
correctly.
2.
Check
the
BMC
log
(see
“Error
logs”
on
page
16).
28
BladeCenter
HS20
Type
7981
and
1884:
Problem
Determination
and
Service
Guide
Содержание eServer BladeCenter HS20Type 8832
Страница 1: ...BladeCenter HS20 Type 7981 and 1884 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter HS20 Type 7981 and 1884 Problem Determination and Service Guide...
Страница 8: ...vi BladeCenter HS20 Type 7981 and 1884 Problem Determination and Service Guide...
Страница 16: ...xiv BladeCenter HS20 Type 7981 and 1884 Problem Determination and Service Guide...
Страница 68: ...52 BladeCenter HS20 Type 7981 and 1884 Problem Determination and Service Guide...
Страница 98: ...82 BladeCenter HS20 Type 7981 and 1884 Problem Determination and Service Guide...
Страница 110: ...94 BladeCenter HS20 Type 7981 and 1884 Problem Determination and Service Guide...
Страница 111: ......
Страница 112: ...Part Number 31R1716 Printed in USA 1P P N 31R1716...