v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
Chapter
3,
“Parts
listing,
Type
7981
and
1884,”
on
page
53
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Beep
code
Description
Action
3-3-1
Memory
size
mismatch
occurred.
1.
Verify
that
both
DIMMs
in
the
bank
are
of
the
same
size,
speed,
type,
and
technology.
2.
Reseat
the
following
components:
a.
DIMMs
b.
Battery
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
blade
server
each
time:
a.
DIMMs
b.
Battery
c.
(Trained
service
technician
only)
System
board
assembly
3-3-2
Critical
SMBUS
error
occurred.
1.
Power
down
the
blade
server
and
reseat
it
in
the
BladeCenter
unit.
2.
Reseat
the
DIMMs.
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
blade
server
each
time:
a.
DIMMs
b.
(Trained
service
technician
only)
System
board
assembly
3-3-3
No
operational
memory
in
system.
Note:
In
some
memory
configurations,
the
3-3-3
beep
code
might
sound
during
POST
followed
by
a
blank
display
screen.
If
this
occurs
and
the
Boot
Fail
Count
feature
in
the
Start
Options
of
the
Configuration/Setup
Utility
is
set
to
Enabled
(its
default
setting),
you
must
restart
the
server
three
times
to
force
the
system
BIOS
code
to
reset
the
memory
connector
or
bank
of
connectors
from
Disabled
to
Enabled.
Important:
In
some
memory
configurations,
the
3-3-3
beep
code
might
sound
during
POST
followed
by
a
blank
display
screen.
If
this
occurs
and
the
Boot
Fail
Count
feature
in
the
Start
Options
of
the
Configuration/Setup
Utility
program
is
set
to
Enabled
(its
default
setting),
you
must
restart
the
blade
server
three
times
to
force
the
system
BIOS
to
reset
the
CMOS
values
to
the
default
configuration
(memory
connector
or
bank
of
connectors
enabled).
1.
Install
or
reseat
DIMMS
and
restart
the
server.
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
blade
server
each
time:
a.
DIMMs
b.
(Trained
service
technician
only)
System
board
assembly
Two
short
beeps
Information
only,
configuration
has
changed.
1.
Run
diagnostics.
2.
Run
the
Configuration/Setup
Utility
program.
14
BladeCenter
HS20
Type
7981
and
1884:
Problem
Determination
and
Service
Guide
Содержание eServer BladeCenter HS20 Type 8832
Страница 1: ...BladeCenter HS20 Type 7981 and 1884 Problem Determination and Service Guide ...
Страница 2: ......
Страница 3: ...BladeCenter HS20 Type 7981 and 1884 Problem Determination and Service Guide ...
Страница 8: ...vi BladeCenter HS20 Type 7981 and 1884 Problem Determination and Service Guide ...
Страница 16: ...xiv BladeCenter HS20 Type 7981 and 1884 Problem Determination and Service Guide ...
Страница 68: ...52 BladeCenter HS20 Type 7981 and 1884 Problem Determination and Service Guide ...
Страница 98: ...82 BladeCenter HS20 Type 7981 and 1884 Problem Determination and Service Guide ...
Страница 110: ...94 BladeCenter HS20 Type 7981 and 1884 Problem Determination and Service Guide ...
Страница 111: ......
Страница 112: ... Part Number 31R1716 Printed in USA 1P P N 31R1716 ...