42
xSeries 380: User’s Reference
3.
Slide the latch on the fan-access door upward, and open the door.
4.
Grasp the fan assembly with the finger holes, and pull the fan assembly out of the
server.
Attention: To maintain proper cooling, do not leave the door open for an
extended time.
5.
Slide the new fan assembly into place.
6.
Close and lock the fan-access door.
7.
Slide the chassis back into the rack.
Replacing a hot-swap 120-mm fan
Your server contains two 120-mm fans, which are accessed from the fan-access door
on the top of the server. Each fan contains a fan-failure light that identifies a failed fan.
Note: The illustrations in this document might differ slightly from your hardware.
Complete the following steps to replace a 120-mm fan:
1.
Review the information in “Safety information” on page 34.
Statement 15
CAUTION:
Make sure that the rack is secured properly to avoid tipping when the server
unit is extended.
2.
Slide the server out of the rack.
3.
Loosen the thumbscrew on the fan-access door, and open the door.
172 mm Fan
Finger hole
Содержание eServer 380 xSeries
Страница 1: ...User s Reference xSeries 380 ...
Страница 2: ......
Страница 3: ...IBM xSeries 380 User s Reference SC06 P464 70 ...
Страница 13: ...Contents xi Index 93 ...
Страница 14: ...xii IBM xSeries 380 User s Reference ...
Страница 18: ...4 xSeries 380 User s Reference ...
Страница 28: ...14 xSeries 380 User s Reference ...
Страница 68: ...54 xSeries 380 User s Reference ...
Страница 110: ...96 IBM xSeries 380 User s Reference ...
Страница 111: ......
Страница 112: ...IBM Part Number 06P4913 Printed in the United States of America 6P4913 ...