Chapter 6. Solving problems
73
175
System thermal
Failed
Fan # n
(where n is the number of the failing fan)
Replace the indicated
fan.
Temperature sensed on processor board is out of
range
Call for service.
180
Status display
Failed
Any failure message
Call for service.
201
System memory
Failed
DIMMs in location DIMM n
(where n is the number of the socket that contains
the failing DIMM)
1.
Reseat the failing
DIMM.
2.
If the problem
remains, replace
the DIMM.
If the problem
persists, call for
service.
Test setup error: Corrupt BIOS code in ROM
If your system does not
have the latest level
BIOS code installed,
update the BIOS code to
the latest level.
If the problem persists,
call for service.
Test setup error: Corrupt DMI BIOS code,
information in BIOS code is not as expected
Code
Function
Result
Text message
Action