Table 22. Symptom-to-FRU index (continued)
Problem indicator Component
Possible cause
Possible solutions
Amber LED is
flashing
Drive CRUs
(Fault LED lit)
Drive identity is in
process
No corrective action needed.
RAID controller
port bypass
A Fibre Channel
loop initialization
process (LIP) is
being generated in
the drive loop due
to a faulty
component.
Use the Read Link Status
window in the Storage Manager
Client Subsystem Management
window and the storage
subsystem event logs to isolate
the faulty component.
Controller
drive port
bypass LED
The enclosure speed
was set to 4 Gbps
but the SFP inserted
in the controller
drive SFP port does
not operate at 4
Gbps.
Use the Recovery Guru menu
function in the Storage Manager
Client Subsystem Management
window to verify the problem
and replace the SFP with a 4
Gbps SFP.
General Fault
LED (located
on the front of
the storage
subsystem)
An intermittent
failure in the
DS3950 storage
subsystem
configuration. The
problem could be
directly related to
the hardware in the
configuration (hard
drive or bad cable)
or indirectly related
to the DS3950
storage subsystem
configuration (such
as a Fibre Channel
host bus adapter
failure in the host
server or the Fibre
Channel switch in
the SAN causing
LUNs to be on a
non-preferred path.)
Use the Recovery Guru menu
function in the Storage Manager
Client Subsystem Management
window to diagnose the
problem.
Chapter 6. Hardware maintenance
159
Содержание DS3950
Страница 1: ...IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide GA32 0953 03...
Страница 2: ......
Страница 3: ...IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide GA32 0953 03...
Страница 8: ...vi IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Страница 12: ...x IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Страница 28: ...xxvi IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Страница 54: ...26 IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Страница 148: ...120 IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Страница 202: ...174 IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Страница 210: ...182 IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Страница 214: ...186 IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Страница 226: ...198 IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Страница 246: ...218 IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Страница 250: ...222 IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Страница 251: ......
Страница 252: ...Part Number 00Y5046 Printed in USA GA32 0953 03 1P P N 00Y5046...