Table
20.
BMC
firmware
messages
(continued)
Event
Severity
Message
Automatic
Action
by
BMC
Action
required
by
user
Cell/B.E.
processor
0
Temp
above
Shut-Off
Temperature
(
95°C)
Error
Processor
1
(BE0
Temp)
critical
fault.
Power
Off
The
temperature
of
the
processor
has
reached
a
critical
level.
v
Check
that
the
BladeCenter
unit
cooling
system
is
operating
correctly.
v
Replace
any
missing
filler
blades
in
the
BladeCenter
unit.
v
Replace
any
missing
filler
blades
in
the
BladeCenter
QS21
DIMM
module
sockets.
v
Check
that
other
blade
servers
are
operating
within
the
recommended
temperature
range.
v
Remove
and
replace
the
blade
server,
power
on
and
boot.
If
problem
persists,
please
contact
IBM
service.
Cell/B.E.
processor
1
Temp
above
Shut-Off
Temperature
(
95°C)
Error
Processor
2
(BE1
Temp)
critical
fault.
Power
Off
The
temperature
of
the
processor
has
reached
a
critical
level.
Temp
above
Shut-Off
Temperature
(100°C)
Error
Processor
3
(SB1
Temp)
critical
fault.
Power
Off
The
temperature
of
the
system
board
has
reached
a
critical
level.
Cell/B.E.
companion
chip
2
Temp
above
Shut-Off
Temperature
(100°C)
Error
Processor
4
(SB2
Temp)
critical
fault.
Power
Off
The
temperature
of
the
system
board
has
reached
a
critical
level.
Cell/B.E.
Events
Processor
Failure
Cell/B.E.
processor
0
(Checkstop)
Error
CPU
1
internal
fault
Reboot
There
may
be
a
problem
with
the
system
board.
If
problem
persists,
please
contact
IBM
service.
Processor
Failure
Cell/B.E.
processor
1
(Checkstop)
Error
CPU
2
internal
fault
Reboot
There
may
be
a
problem
with
the
system
board.
If
problem
persists,
please
contact
IBM
service.
Failure
Initializing
Cell/B.E.
processor
0
or
Cell/B.E.
companion
chip
0
Error
CPU
1
Fault
+
″
Init
Failed
#x
″
,
where
x
is
a
number
representing
the
error
condition
Power
Off
Reboot.
If
the
problem
persists,
the
blade
needs
to
be
replaced.
Failure
Initializing
Cell/B.E.
processor
1
or
Cell/B.E.
companion
chip
1
Error
CPU
2
Fault
Power
Off
Chapter
5.
Diagnostics
and
troubleshooting
91
Содержание BladeCenter QS21 Type 0792
Страница 1: ...BladeCenter QS21 Type 0792 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter QS21 Type 0792 Problem Determination and Service Guide...
Страница 8: ...vi BladeCenter QS21 Type 0792 Problem Determination and Service Guide...
Страница 46: ...28 BladeCenter QS21 Type 0792 Problem Determination and Service Guide...
Страница 68: ...50 BladeCenter QS21 Type 0792 Problem Determination and Service Guide...
Страница 142: ...124 BladeCenter QS21 Type 0792 Problem Determination and Service Guide...
Страница 143: ......
Страница 144: ...Part Number 42C4969 Printed in USA 1P P N 42C4969...