Table 18. BA000010 to BA400002 Partition firmware SRCs (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v
See Chapter 3, “Parts listing, type 7891,” on page 225 to determine which components are CRUs and which
components are FRUs.
Error code
Description
Action
BA000070
The firmware was unable to load the
open firmware code lid
1.
Reboot the blade server.
2.
If the problem persists:
a.
Go to “Checkout procedure” on page
176.
b.
Replace the system-board, as described
in “Replacing the FRU system-board
and chassis assembly” on page 264.
BA000080
The user did not accept the license
agreement
Accept the license agreement and restart the
blade server.
If the problem persists:
1.
Go to “Checkout procedure” on page 176.
2.
Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 264.
BA000081
Failed to get the firmware license policy
1.
Reboot the blade server.
2.
If the problem persists:
a.
Go to “Checkout procedure” on page
176.
b.
Replace the system-board, as described
in “Replacing the FRU system-board
and chassis assembly” on page 264.
BA000082
Failed to set the firmware license policy
1.
Reboot the blade server.
2.
If the problem persists:
a.
Go to “Checkout procedure” on page
176.
b.
Replace the system-board, as described
in “Replacing the FRU system-board
and chassis assembly” on page 264.
BA000091
Unable to load a firmware code update
module
1.
Reboot the blade server.
2.
If the problem persists:
a.
Go to “Checkout procedure” on page
176.
b.
Replace the system-board, as described
in “Replacing the FRU system-board
and chassis assembly” on page 264.
BA00E820
An lpevent communication failure
occurred
1.
Go to “Checkout procedure” on page 176.
2.
Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 264.
BA00E830
Failure when initializing ibm,event-scan
1.
Go to “Checkout procedure” on page 176.
2.
Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 264.
Chapter 2. Diagnostics
63
Содержание BladeCenter PS703
Страница 2: ......
Страница 26: ...14 Power Systems Problem Determination and Service Guide for the IBM PS703 7891 73X and PS704 7891 74X...
Страница 240: ...228 Power Systems Problem Determination and Service Guide for the IBM PS703 7891 73X and PS704 7891 74X...
Страница 278: ...266 Power Systems Problem Determination and Service Guide for the IBM PS703 7891 73X and PS704 7891 74X...
Страница 286: ...274 Power Systems Problem Determination and Service Guide for the IBM PS703 7891 73X and PS704 7891 74X...
Страница 297: ......
Страница 298: ...Printed in USA GI11 9841 00...