Power
error
messages
Power
to
the
blade
workstation
is
provided
by
shared
BladeCenter
unit
resources.
See
the
following
table
and
“Solving
shared
BladeCenter
resource
problems”
on
page
75.
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
Chapter
3,
“Parts
listing,
Type
7996,”
on
page
11
to
determine
which
components
are
CRUs
and
which
components
are
FRUs.
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Message
Action
System
Power
Good
fault
1.
Reseat
the
blade
workstation.
2.
Check
the
function
of
the
shared
BladeCenter
unit
resources
(see
“Solving
shared
BladeCenter
resource
problems”
on
page
75).
3.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
VRD
Power
Good
fault
1.
Reseat
the
blade
workstation.
2.
Check
the
function
of
the
shared
BladeCenter
unit
resources
(see
“Solving
shared
BladeCenter
resource
problems”
on
page
75).
3.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
System
over
recommended
voltage
for
+12v.
Informational
only.
Note:
If
the
problem
persists,
perform
the
following
tasks.
1.
Reseat
the
blade
workstation.
2.
Check
the
function
of
the
shared
BladeCenter
unit
resources
(see
“Solving
shared
BladeCenter
resource
problems”
on
page
75.
3.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
System
over
recommended
voltage
for
+3.3v.
Informational
only.
Note:
If
the
problem
persists,
perform
the
following
tasks.
1.
Reseat
the
blade
workstation.
2.
Check
the
function
of
the
shared
BladeCenter
unit
resources
(see
“Solving
shared
BladeCenter
resource
problems”
on
page
75.
3.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
System
over
recommended
5V
fault.
Informational
only.
Note:
If
the
problem
persists,
perform
the
following
tasks.
1.
Reseat
the
blade
workstation.
2.
Check
the
function
of
the
shared
BladeCenter
unit
resources
(see
“Solving
shared
BladeCenter
resource
problems”
on
page
75.
3.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
System
under
recommended
voltage
for
+12v.
Informational
only.
Note:
If
the
problem
persists,
perform
the
following
tasks.
1.
Reseat
the
blade
workstation.
2.
Check
the
function
of
the
shared
BladeCenter
unit
resources
(see
“Solving
shared
BladeCenter
resource
problems”
on
page
75.
3.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
Chapter
5.
Diagnostics
63
Содержание BladeCenter HC10 Type 7996
Страница 1: ...BladeCenter HC10 Type 7996 Problem Determination and Service Guide ...
Страница 2: ......
Страница 3: ...BladeCenter HC10 Type 7996 Problem Determination and Service Guide ...
Страница 8: ...vi BladeCenter HC10 Type 7996 Problem Determination and Service Guide ...
Страница 16: ...xiv BladeCenter HC10 Type 7996 Problem Determination and Service Guide ...
Страница 54: ...38 BladeCenter HC10 Type 7996 Problem Determination and Service Guide ...
Страница 112: ...96 BladeCenter HC10 Type 7996 Problem Determination and Service Guide ...
Страница 113: ......
Страница 114: ... Part Number 42C4881 Printed in USA 1P P N 42C4881 ...