Table
2.
Firmware
Checkpoints
(continued)
Checkpoint
Description
Action/
Possible
Failing
FRU
E5E7
Save
I/O
hub
information
for
RTAS
and
open
firmware
1.
Check
for
system
firmware
updates.
2.
Go
to
“MAP
1540:
Problem
Isolation
Procedures”
on
page
87.
E5E8
Set
up
registers
1.
Check
for
system
firmware
updates.
2.
Go
to
“MAP
1540:
Problem
Isolation
Procedures”
on
page
87.
E5E9
Reset
the
quick
restart
path
1.
Check
for
system
firmware
updates.
2.
Go
to
“MAP
1540:
Problem
Isolation
Procedures”
on
page
87.
E5EE
Hang
state
in
main
control
code
1.
Check
for
system
firmware
updates.
2.
Go
to
“MAP
1540:
Problem
Isolation
Procedures”
on
page
87.
E5EF
End
of
low-level
firmware
1.
Check
for
system
firmware
updates.
2.
Go
to
“MAP
1540:
Problem
Isolation
Procedures”
on
page
87.
E5FE
Get
the
system’s
licensed
memory
quantity
from
the
service
processor
1.
Replace
the
I/O
drawer
subsystem
backplane
specified
by
the
location
code.
2.
Power
down,
then
power
up
the
system.
3.
Call
service
support.
E600
SSA
PCI
adapter
open
firmware
has
run
successfully.
Replace
the
adapter.
E601
SSA
PCI
adapter
BIST
has
started
but
failed
to
complete
after
4
seconds.
Replace
the
adapter.
E602
SSA
PCI
open
firmware
has
started.
Replace
the
adapter.
E603
SSA
PCI
adapter
BIST
has
completed
with
an
error.
Replace
the
adapter.
E604
SSA
PCI
adapter
BIST
and
subsequent
POSTs
have
completed
successfully.
Replace
the
adapter.
E605
SSA
PCI
adapter
BIST
has
completed
successfully
but
subsequent
POSTS
have
failed.
Replace
the
adapter.
E60E
SSA
PCI
open
firmware
about
to
exit
(no
stack
corruption).
Replace
the
adapter.
E60F
SSA
PCI
open
firmware
has
run
unsuccessfully.
Replace
the
adapter.
E6FF
SSA
PCI
open
firmware
about
to
exit
(with
stack
corruption).
Replace
the
adapter.
E700
Create
system
firmware
VPD
System
firmware
may
be
corrupted.
Reinstall
system
firmware.
E701
Create
memory
VPD.
1.
Check
for
system
firmware
updates.
2.
Call
for
support.
124
IntelliStation
POWER
9114
Model
275
Service
Guide
Содержание 9114-275 - IntelliStation POWER 275
Страница 1: ...IntelliStation POWER 9114 Model 275 Service Guide SA38 0636 00 ...
Страница 2: ......
Страница 3: ...IntelliStation POWER 9114 Model 275 Service Guide SA38 0636 00 ...
Страница 14: ...xii IntelliStation POWER 9114 Model 275 Service Guide ...
Страница 16: ...xiv IntelliStation POWER 9114 Model 275 Service Guide ...
Страница 50: ...32 IntelliStation POWER 9114 Model 275 Service Guide ...
Страница 58: ...40 IntelliStation POWER 9114 Model 275 Service Guide ...
Страница 81: ...Yes Go to Step 1321 16 on page 64 Chapter 3 Maintenance Analysis Procedures MAPs 63 ...
Страница 210: ...192 IntelliStation POWER 9114 Model 275 Service Guide ...
Страница 246: ...228 IntelliStation POWER 9114 Model 275 Service Guide ...
Страница 319: ...Chapter 10 Parts Information This chapter contains parts information for the IntelliStation POWER 9114 Model 275 301 ...
Страница 320: ...System Parts 302 IntelliStation POWER 9114 Model 275 Service Guide ...
Страница 330: ...312 IntelliStation POWER 9114 Model 275 Service Guide ...
Страница 332: ...314 IntelliStation POWER 9114 Model 275 Service Guide ...
Страница 336: ...318 IntelliStation POWER 9114 Model 275 Service Guide ...
Страница 340: ...322 IntelliStation POWER 9114 Model 275 Service Guide ...
Страница 375: ......
Страница 376: ... Printed in U S A July 2003 SA38 0636 00 ...
Страница 377: ...Spine information IntelliStation POWER 9114 Model 275 IntelliStation POWER 9114 Model 275 Service Guide SA38 0636 00 ...