v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
Chapter
3,
“Parts
listing,
Type
8872
and
Type
8874,”
on
page
93
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
code
Description
Action
217-xxx-003
Failed
BIOS
fixed
disk
test.
Note:
If
RAID
is
configured,
the
fixed
disk
number
refers
to
the
RAID
logical
array.
1.
Reseat
hard
disk
drive
4.
2.
Replace
hard
disk
drive
4.
217-xxx-004
Failed
BIOS
fixed
disk
test.
Note:
If
RAID
is
configured,
the
fixed
disk
number
refers
to
the
RAID
logical
array.
1.
Reseat
hard
disk
drive
5.
2.
Replace
hard
disk
drive
5.
217-xxx-005
Failed
BIOS
fixed
disk
test.
Note:
If
RAID
is
configured,
the
fixed
disk
number
refers
to
the
RAID
logical
array.
1.
Reseat
hard
disk
drive
6.
2.
Replace
hard
disk
drive
6.
217-198-xxx
Could
not
establish
drive
parameters.
1.
Check
the
drive
cables
and
terminators.
2.
Reseat
the
hard
disk
drive.
3.
Replace
the
hard
disk
drive.
301-xxx-000
Failed
keyboard
test.
Note:
After
installing
a
USB
keyboard,
you
might
have
to
use
the
Configuration/Setup
Utility
program
to
enable
keyboardless
operation
and
prevent
the
POST
error
message
301
from
being
displayed
during
startup.
1.
Reseat
the
following
components:
a.
Keyboard
b.
I/O
board
2.
Replace
the
components
listed
in
step
1
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
302-xxx-xxx
Failed
mouse
test.
1.
Reseat
the
following
components:
a.
Mouse
b.
I/O
board
2.
Replace
the
components
listed
in
step
1
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
305-xxx-xxx
Failed
video
monitor
test.
1.
Reseat
the
following
components:
a.
Monitor
b.
I/O
board
2.
Replace
the
components
listed
in
step
1
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
405-xxx-000
Failed
Ethernet
test
on
controller
on
I/O
board.
1.
Make
sure
that
Ethernet
is
not
disabled
in
the
Configuration/Setup
Utility
program
and
that
the
BIOS
code
is
at
the
latest
level.
2.
Run
the
loopback
diagnostic.
3.
Reseat
the
I/O
board.
4.
Replace
the
I/O
board.
405-xxx-00n
No
good
link!
Check
loopback
plug.
1.
Make
sure
that
the
loopback
plug
is
a
gigabit
loopback
plug
(see
“Solving
Ethernet
controller
problems”
on
page
88).
2.
Check
for
any
loose
connections
between
the
loopback
plug
and
the
Ethernet
connector.
76
IBM
xSeries
460
Type
8872
and
xSeries
MXE
460
Type
8874:
Problem
Determination
and
Service
Guide
Содержание 8872 - eServer xSeries 460
Страница 2: ......
Страница 8: ...vi IBM xSeries 460 Type 8872 and xSeries MXE 460 Type 8874 Problem Determination and Service Guide ...
Страница 28: ...12 IBM xSeries 460 Type 8872 and xSeries MXE 460 Type 8874 Problem Determination and Service Guide ...
Страница 108: ...92 IBM xSeries 460 Type 8872 and xSeries MXE 460 Type 8874 Problem Determination and Service Guide ...
Страница 114: ...98 IBM xSeries 460 Type 8872 and xSeries MXE 460 Type 8874 Problem Determination and Service Guide ...
Страница 148: ...132 IBM xSeries 460 Type 8872 and xSeries MXE 460 Type 8874 Problem Determination and Service Guide ...
Страница 158: ...142 IBM xSeries 460 Type 8872 and xSeries MXE 460 Type 8874 Problem Determination and Service Guide ...
Страница 169: ......
Страница 170: ... Part Number 25K8124 Printed in USA 1P P N 25K8124 ...