v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
Chapter
3,
“Parts
listing,
Type
8872
and
Type
8874,”
on
page
93
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
code
Description
Action
180-xxx-007
Failed
power
supply
fan
LED
test.
1.
Reseat
the
following
components:
a.
Power
supply
b.
(Trained
service
technician
only)
Power
supply
structure
c.
I/O
board
2.
Replace
the
components
listed
in
step
1
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
180-xxx-008
Failed
I/O
board
LED
test.
1.
Reseat
the
I/O
board.
2.
Replace
the
I/O
board.
180-xxx-009
Failed
Active
™
PCI
LED
test.
1.
Reseat
the
following
components:
a.
(Trained
service
technician
only)
PCI-X
switch
card
assembly
b.
I/O
board
2.
Replace
the
components
listed
in
step
1
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
201-198-000
Memory
Test
Aborted:
Could
not
run
the
test;
suspect
microprocessor
tray
error.
1.
Restart
the
server.
2.
Run
the
diagnostic
test
again.
3.
Reinstall
the
diagnostic
programs
(see
“Updating
the
firmware”
on
page
133).
4.
(Trained
service
technician
only)
Replace
the
microprocessor
tray.
201-198-00n
Memory
Test
Aborted:
Could
not
run
the
test.
Note:
n
=
1-9
(programming
error).
1.
Restart
the
server.
2.
Run
the
diagnostic
test
again.
3.
Reinstall
the
diagnostic
programs
(see
“Updating
the
firmware”
on
page
133).
201-xxx-CBN
Failed
Memory
Test:
See
“Memory
card
and
memory
module
(DIMM)”
on
page
108.
v
C
=
memory
card
[1-4]
v
B
=
physical
bank
[1-2]
Note:
Bank
1
=
DIMMs
1
and
3;
Bank
2
=
DIMMs
2
and
4
v
N
=
failing
DIMM
[1-4]
1.
Reseat
the
following
components:
a.
DIMM
N
b.
Memory
card
C
2.
Replace
the
components
listed
in
step
1
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
Note:
N
=
9
indicates
both
DIMMs
in
physical
bank
B
and
memory
card
C.
74
IBM
xSeries
460
Type
8872
and
xSeries
MXE
460
Type
8874:
Problem
Determination
and
Service
Guide
Содержание 8872 - eServer xSeries 460
Страница 2: ......
Страница 8: ...vi IBM xSeries 460 Type 8872 and xSeries MXE 460 Type 8874 Problem Determination and Service Guide ...
Страница 28: ...12 IBM xSeries 460 Type 8872 and xSeries MXE 460 Type 8874 Problem Determination and Service Guide ...
Страница 108: ...92 IBM xSeries 460 Type 8872 and xSeries MXE 460 Type 8874 Problem Determination and Service Guide ...
Страница 114: ...98 IBM xSeries 460 Type 8872 and xSeries MXE 460 Type 8874 Problem Determination and Service Guide ...
Страница 148: ...132 IBM xSeries 460 Type 8872 and xSeries MXE 460 Type 8874 Problem Determination and Service Guide ...
Страница 158: ...142 IBM xSeries 460 Type 8872 and xSeries MXE 460 Type 8874 Problem Determination and Service Guide ...
Страница 169: ......