Error
code
Description
Action
202-xxx-0nn
Failed
system
cache
test,
where
nn=APIC
ID.
APIC
ID
Microprocessor
00,
01
1
06,
07
2
10,
11
3
16,
17
4
1.
Reseat
the
following
components:
a.
(Trained
service
technician
only)
Microprocessor
nn
b.
Microprocessor
tray
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
a.
(Trained
service
technician
only)
Microprocessor
nn
b.
(Trained
service
technician
only)
Microprocessor
tray
204-198-000
Test
aborted.
1.
Run
the
Quick
Memory
Test
Diagnostic
All
Banks
(see
“Running
the
diagnostic
programs”
on
page
59).
2.
Update
the
BIOS
code
(see
“Updating
the
firmware”
on
page
133).
3.
Look
in
the
test
log
(see
“Viewing
the
test
log”
on
page
60)
and
correct
any
other
errors.
204-210-000
Test
failed.
1.
Run
the
Quick
Memory
Test
Diagnostic
All
Banks
(see
“Running
the
diagnostic
programs”
on
page
59).
2.
Update
the
BIOS
code
(see
“Updating
the
firmware”
on
page
133).
3.
Look
in
the
test
log
(see
“Viewing
the
test
log”
on
page
60)
and
correct
any
other
errors.
215-xxx-000
Failed
CD
or
DVD
test.
1.
Run
the
test
again
with
a
different
CD
or
DVD.
2.
Reseat
the
following
components:
a.
CD
or
DVD
drive
b.
Front
panel
assembly
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
CD
or
DVD
drive
b.
(Trained
service
technician
only)
Front
panel
assembly
217-xxx-000
Failed
BIOS
fixed
disk
test.
Note:
If
RAID
is
configured,
the
fixed
disk
number
refers
to
the
RAID
logical
array.
1.
Reseat
hard
disk
drive
1.
2.
Replace
hard
disk
drive
1.
217-xxx-001
Failed
BIOS
fixed
disk
test.
Note:
If
RAID
is
configured,
the
fixed
disk
number
refers
to
the
RAID
logical
array.
1.
Reseat
hard
disk
drive
2.
2.
Replace
hard
disk
drive
2.
217-xxx-002
Failed
BIOS
fixed
disk
test.
Note:
If
RAID
is
configured,
the
fixed
disk
number
refers
to
the
RAID
logical
array.
1.
Reseat
hard
disk
drive
3.
2.
Replace
hard
disk
drive
3.
Chapter
2.
Diagnostics
75
Содержание 8872 - eServer xSeries 460
Страница 2: ......
Страница 8: ...vi IBM xSeries 460 Type 8872 and xSeries MXE 460 Type 8874 Problem Determination and Service Guide ...
Страница 28: ...12 IBM xSeries 460 Type 8872 and xSeries MXE 460 Type 8874 Problem Determination and Service Guide ...
Страница 108: ...92 IBM xSeries 460 Type 8872 and xSeries MXE 460 Type 8874 Problem Determination and Service Guide ...
Страница 114: ...98 IBM xSeries 460 Type 8872 and xSeries MXE 460 Type 8874 Problem Determination and Service Guide ...
Страница 148: ...132 IBM xSeries 460 Type 8872 and xSeries MXE 460 Type 8874 Problem Determination and Service Guide ...
Страница 158: ...142 IBM xSeries 460 Type 8872 and xSeries MXE 460 Type 8874 Problem Determination and Service Guide ...
Страница 169: ......
Страница 170: ... Part Number 25K8124 Printed in USA 1P P N 25K8124 ...