v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
Chapter
3,
“Parts
listing,
Type
8872
and
Type
8874,”
on
page
93
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Beep
code
Description
Action
Two
long
and
two
short
beeps
Card
error.
1.
Reseat
the
following
components:
a.
Microprocessor
tray
b.
I/O
board
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
a.
(Trained
service
technician
only)
Microprocessor
tray
b.
I/O
board
No-beep
symptoms
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
Chapter
3,
“Parts
listing,
Type
8872
and
Type
8874,”
on
page
93
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only)”,
that
step
must
be
performed
only
by
a
trained
service
technician.
No-beep
symptom
Description
Action
No
beeps
occur,
and
the
system
operates
correctly.
1.
(Trained
service
technician
only)
Reseat
the
operator
information
panel.
2.
(Trained
service
technician
only)
Replace
the
operator
information
panel.
No
beeps
occur
after
successful
completion
of
POST.
The
power-on
status
is
Disabled.
1.
Run
the
Configuration/Setup
Utility
program
and
select
Start
Options
;
then,
set
Power-On
Status
to
Enable
.
2.
(Trained
service
technician
only)
Reseat
the
operator
information
panel.
3.
(Trained
service
technician
only)
Replace
the
operator
information
panel.
No
beeps
occur,
and
there
is
no
video.
See
“Solving
undetermined
problems”
on
page
90.
Error
logs
The
POST
error
log
contains
the
three
most
recent
error
codes
and
messages
that
were
generated
during
POST.
The
BMC
log
and
the
system-error
log
contain
messages
that
were
generated
during
POST
and
all
system
status
messages
from
the
service
processor.
The
following
illustration
shows
an
example
of
a
BMC
log
entry.
18
IBM
xSeries
460
Type
8872
and
xSeries
MXE
460
Type
8874:
Problem
Determination
and
Service
Guide
Содержание 8872 - eServer xSeries 460
Страница 2: ......
Страница 8: ...vi IBM xSeries 460 Type 8872 and xSeries MXE 460 Type 8874 Problem Determination and Service Guide ...
Страница 28: ...12 IBM xSeries 460 Type 8872 and xSeries MXE 460 Type 8874 Problem Determination and Service Guide ...
Страница 108: ...92 IBM xSeries 460 Type 8872 and xSeries MXE 460 Type 8874 Problem Determination and Service Guide ...
Страница 114: ...98 IBM xSeries 460 Type 8872 and xSeries MXE 460 Type 8874 Problem Determination and Service Guide ...
Страница 148: ...132 IBM xSeries 460 Type 8872 and xSeries MXE 460 Type 8874 Problem Determination and Service Guide ...
Страница 158: ...142 IBM xSeries 460 Type 8872 and xSeries MXE 460 Type 8874 Problem Determination and Service Guide ...
Страница 169: ......
Страница 170: ... Part Number 25K8124 Printed in USA 1P P N 25K8124 ...