v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
Chapter
3,
“Parts
listing,
Type
8863,”
on
page
93
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only)”,
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
code
Description
Action
035-277-001
Adapter
Local
RAM
test
error.
1.
Update
the
RAID
controller
firmware
(see
“Updating
the
firmware”
on
page
133).
2.
Reseat
and,
if
necessary,
replace
the
RAID
controller.
035-278-001
Adapter
NVSRAM
test
error.
1.
Update
the
RAID
controller
firmware
(see
“Updating
the
firmware”
on
page
133).
2.
Reseat
and,
if
necessary,
replace
the
RAID
controller.
035-279-001
Adapter
Cache
test
error.
1.
Update
the
RAID
controller
firmware
(see
“Updating
the
firmware”
on
page
133).
2.
Reseat
and,
if
necessary,
replace
the
RAID
controller.
035-280-001
Adapter
Drive
test
error.
Replace
the
attached
drive.
035-281-001
Adapter
Drive
error.
Replace
the
attached
drive.
035-282-001
Adapter
Parameters
set
error.
1.
Update
the
RAID
controller
firmware
(see
“Updating
the
firmware”
on
page
133).
2.
Reseat
and,
if
necessary,
replace
the
RAID
controller.
035-283-001
Adapter
Battery
error.
Replace
the
battery
module
on
the
RAID
controller.
035-xxx-cnn
c
=
ServeRAID
channel
number,
nn
=
SCSI
ID
of
failing
fixed
disk
drive.
1.
Check
the
BMC
log
or
system-error
log
before
replacing
a
FRU.
2.
Reseat
and,
if
necessary,
replace
the
hard
disk
drive
on
channel
C,
SCSI
ID
nn.
035-xxx-snn
nn
=
SCSI
ID
of
failing
fixed
disk.
1.
Check
the
BMC
log
or
system-error
log
before
replacing
a
FRU.
2.
Reseat
and,
if
necessary,
replace
the
SCSI
disk
with
ID
nn
on
adapter
in
slot
s
075-xxx-000
Failed
power
supply
test.
1.
Reseat
the
following
components:
a.
Power
supply
b.
(Trained
service
technician
only)
Power
backplane
2.
Replace
the
components
listed
in
step
1
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
66
IBM
xSeries
366
Type
8863:
Problem
Determination
and
Service
Guide
Содержание 8863 - eServer xSeries 366
Страница 1: ...IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Страница 8: ...vi IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Страница 28: ...12 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Страница 114: ...98 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Страница 148: ...132 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Страница 158: ...142 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Страница 169: ...V video connector 6 VRM LED 52 W Web site 1 weight 3 World Wide Web 1 Index 153...
Страница 170: ...154 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Страница 171: ......
Страница 172: ...Part Number 31R1508 Printed in USA 1P P N 31R1508...