v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
Chapter
3,
“Parts
listing,
Type
8863,”
on
page
93
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only)”,
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
code
Description
Action
030-xxx-00n
Failed
SCSI
test
on
PCI
slot
n
where
n
represents
the
slot
number
of
the
failing
adapter.
1.
Check
the
BMC
log
or
system-error
log
before
replacing
a
CRU
or
FRU
(see“Error
logs”
on
page
18).
2.
Reseat
and,
if
necessary,
replace
the
adapter
in
slot
n.
035-002-0nn
ServeRAID
interface
timeout.
1.
The
ServeRAID
controller
might
not
be
configured
correctly.
Obtain
the
basic
and
extended
configuration
status
bytes
and
see
the
ServeRAID
Hardware
Maintenance
Manual
for
more
information.
2.
Reseat
the
following
components:
a.
SAS
hard
disk
drive
backplane
cables
b.
ServeRAID
controller
3.
Replace
the
components
listed
in
step
2
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
035-253-0nn
ServeRAID
controller
0nn
initialization
failure;
0nn
=
the
controller
number.
1.
The
ServeRAID
controller
might
not
be
configured
correctly.
See
the
ServeRAID
Hardware
Maintenance
Manual
for
more
information.
2.
Reseat
the
following
components:
a.
SAS
hard
disk
drive
backplane
cables
b.
ServeRAID
controller
3.
Replace
the
components
listed
in
step
2
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
035-253-s99
RAID
adapter
initialization
failure.
1.
Reseat
the
following
components:
a.
ServeRAID
adapter
b.
SAS
hard
disk
drive
backplane
cable
2.
Replace
the
components
listed
in
step
1
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
035-254-0nn
Setup
error;
unable
to
allocate
memory
to
run
test.
Check
the
system
resources
and
make
more
memory
available
(see
“Configuration/Setup
Utility
menu
choices”
on
page
135);
then,
run
the
test
again.
035-255-0nn
Internal
error.
1.
Reseat
the
SAS
hard
disk
drive
backplane
cable.
2.
Replace
the
SAS
hard
disk
drive
backplane.
035-260-0nn
System
to
controller
interface
failure.
1.
Reseat
the
following
components:
a.
ServeRAID
adapter
b.
I/O
board
2.
Replace
the
components
listed
in
step
1
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
64
IBM
xSeries
366
Type
8863:
Problem
Determination
and
Service
Guide
Содержание 8863 - eServer xSeries 366
Страница 1: ...IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Страница 8: ...vi IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Страница 28: ...12 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Страница 114: ...98 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Страница 148: ...132 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Страница 158: ...142 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Страница 169: ...V video connector 6 VRM LED 52 W Web site 1 weight 3 World Wide Web 1 Index 153...
Страница 170: ...154 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Страница 171: ......
Страница 172: ...Part Number 31R1508 Printed in USA 1P P N 31R1508...