1.
Check
the
light
path
diagnostics
LEDs
on
the
operator
information
panel
(see
“Light
path
diagnostics”
on
page
48).
2.
Remove
the
software
or
device
that
you
just
added.
3.
Run
the
diagnostic
tests
to
determine
whether
the
server
is
running
correctly.
4.
Reinstall
the
new
software
or
new
device.
CD
or
DVD
drive
problems
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
Chapter
3,
“Parts
listing,
Type
8863,”
on
page
93
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only)”,
that
step
must
be
performed
only
by
a
trained
service
technician.
Symptom
Action
The
CD
or
DVD
drive
is
not
recognized.
1.
Make
sure
that:
v
The
IDE
channel
to
which
the
CD
or
DVD
drive
is
attached
(primary
or
secondary)
is
enabled
in
the
Configuration/Setup
Utility
program.
v
All
cables
and
jumpers
are
installed
correctly.
v
The
correct
device
driver
is
installed
for
the
CD
or
DVD
drive.
2.
Run
the
CD
or
DVD
drive
diagnostic
programs.
3.
Reseat
the
following
components:
a.
CD
or
DVD
drive
b.
CD
or
DVD
drive
cable
c.
I/O
board
4.
Replace
the
components
listed
in
step
3
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
A
CD
or
DVD
is
not
working
correctly.
1.
Clean
the
CD
or
DVD.
2.
Run
the
CD
or
DVD
drive
diagnostic
programs.
3.
Reseat
the
CD
or
DVD
drive.
4.
Replace
the
CD
or
DVD
drive.
The
CD
or
DVD
drive
tray
is
not
working.
1.
Make
sure
that
the
server
is
turned
on.
2.
Insert
the
end
of
a
straightened
paper
clip
into
the
manual
tray-release
opening.
3.
Reseat
the
CD
or
DVD
drive.
4.
Replace
the
CD
or
DVD
drive.
36
IBM
xSeries
366
Type
8863:
Problem
Determination
and
Service
Guide
Содержание 8863 - eServer xSeries 366
Страница 1: ...IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Страница 8: ...vi IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Страница 28: ...12 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Страница 114: ...98 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Страница 148: ...132 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Страница 158: ...142 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Страница 169: ...V video connector 6 VRM LED 52 W Web site 1 weight 3 World Wide Web 1 Index 153...
Страница 170: ...154 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Страница 171: ......
Страница 172: ...Part Number 31R1508 Printed in USA 1P P N 31R1508...