v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
System
event/error
log
message
Action
Memory
area
non-critical
over
temperature
warning
1.
Make
sure
that
the
fans
are
operating
and
are
not
obstructed.
2.
Make
sure
that
the
air
baffles
are
in
place
and
correctly
installed.
3.
Make
sure
that
the
server
cover
is
installed
and
fully
closed.
Memory
area
non-recoverable
over
temperature
fault
1.
Make
sure
that
the
fans
are
operating
and
are
not
obstructed.
2.
Make
sure
that
the
air
baffles
are
in
place
and
correctly
installed.
3.
Make
sure
that
the
server
cover
is
installed
and
fully
closed.
4.
(Trained
service
technician
only)
Replace
the
system
board.
Fan
n
failure
n
=
the
fan
number
1.
Make
sure
that
the
connector
on
the
fan
is
not
damaged.
2.
Make
sure
that
the
fan
connector
on
the
system
board
is
not
damaged.
3.
Make
sure
that
the
fan
is
fully
installed
(press
down
on
the
fan).
4.
Reseat
fan
n.
5.
Replace
fan
n
.
Fan
n
fault
n
=
the
fan
number
1.
Make
sure
that
the
connector
on
the
fan
is
not
damaged.
2.
Make
sure
that
the
fan
connector
on
the
system
board
is
not
damaged.
3.
Make
sure
that
the
fan
is
fully
installed
(press
down
on
the
fan).
4.
Reseat
fan
n
.
5.
Replace
fan
n
.
Hard
drive
n
fault
n
=
the
hard
disk
drive
number
1.
Reseat
hard
disk
drive
n
.
2.
Replace
hard
disk
drive
n.
Hard
drive
n
removal
detected
n
=
the
hard
disk
drive
number
Reseat
hard
disk
drive
n
.
HT1000
initiated
sync
flood:
Legacy
I/O
Failure
(Trained
service
technician
only)
Replace
the
system
board.
HT1000
initiated
sync
flood:
PERR
on
PCI-x
slot
1.
Reseat
the
failing
adapter.
2.
Replace
the
failing
adapter.
3.
(Trained
service
technician
only)
Replace
the
system
board.
HT1000
initiated
sync
flood:
SERR
on
PCI-x
slot
1.
Reseat
the
failing
adapter.
2.
Replace
the
failing
adapter.
3.
(Trained
service
technician
only)
Replace
the
system
board.
Power
supply
n
removed
n
=
the
power
supply
number
1.
Reseat
power
supply
n
.
2.
Replace
power
supply
n
.
3.
Replace
the
power
backplane.
72
IBM
System
x3655
Type
7985
and
7943:
Problem
Determination
and
Service
Guide
Содержание 7943
Страница 1: ...IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide ...
Страница 2: ......
Страница 3: ...IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide ...
Страница 8: ...vi IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide ...
Страница 18: ...xvi IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide ...
Страница 36: ...18 IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide ...
Страница 110: ...92 IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide ...
Страница 112: ...View 1 ...
Страница 159: ...Battery Chapter 5 Removing and replacing server components 141 ...
Страница 202: ...184 IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide ...
Страница 212: ...194 IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide ...
Страница 217: ......
Страница 218: ... Part Number 42D2167 Printed in USA 1P P N 42D2167 ...