v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
code
Description
Action
201-199-xxx
Unexpected
error.
Test
aborted.
1.
Restart
the
server.
2.
Run
the
diagnostic
test
again.
3.
Reinstall
the
diagnostic
programs
(see
4.
Check
the
system
event/error
log
and
the
BMC
log
for
messages
that
indicate
the
cause
of
the
error,
and
take
the
indicated
action.
201-xxx-PBD
Test
failed:
v
P
=
microprocessor
[1
-
2]
v
B
=
Failing
bank/pair
number
v
D
=
Failing
DIMM
number
within
failing
CPU
#P
Note:
If
D
=
9,
both
DIMMS
in
the
bank
failed.
1.
Reseat
the
failing
DIMMs;
then,
run
the
memory
diagnostic
test
again.
2.
Replace
the
failing
DIMMs;
then,
run
the
memory
diagnostic
test
again.
3.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
202-xxx-0nn
Failed
system
cache
test.
Note:
nn
=
APIC
ID
for
failing
microprocessor
v
0,
1
=
microprocessor
1
v
2,
3
=
microprocessor
2
1.
Make
sure
that
the
BIOS
code
is
at
the
latest
level.
2.
(Trained
service
technician
only)
Reseat
the
indicated
microprocessor.
3.
(Trained
service
technician
only)
Replace
the
indicated
microprocessor.
215-xxx-000
Failed
CD-RW/DVD
drive
test.
1.
Run
the
test
again
with
a
different
CD-RW/DVD
drive.
2.
Reseat
the
following
components:
a.
CD-RW/DVD
drive
b.
Operator
information
panel
assembly
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
CD-RW/DVD
drive
b.
CD-RW/DVD
media
backplane
217-198-xxx
Could
not
establish
drive
parameters.
1.
Reseat
the
hard
disk
drive
signal
cable.
2.
Reseat
the
hard
disk
drive.
3.
Replace
the
following
components
in
the
order
shown,
restarting
the
server
each
time:
a.
Hard
disk
drive
b.
Hard
disk
drive
signal
cable
c.
Hard
disk
drive
backplane
217-xxx-00n
Failed
fixed
disk
test.
Note:
n
is
the
number
of
the
failed
drive.
The
hard
disk
drive
numbers
are
on
the
server
front.
1.
Reseat
the
hard
disk
drive
indicated
by
n.
2.
Replace
the
hard
disk
drive
indicated
by
n.
66
IBM
System
x3655
Type
7985
and
7943:
Problem
Determination
and
Service
Guide
Содержание 7943
Страница 1: ...IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide ...
Страница 2: ......
Страница 3: ...IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide ...
Страница 8: ...vi IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide ...
Страница 18: ...xvi IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide ...
Страница 36: ...18 IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide ...
Страница 110: ...92 IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide ...
Страница 112: ...View 1 ...
Страница 159: ...Battery Chapter 5 Removing and replacing server components 141 ...
Страница 202: ...184 IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide ...
Страница 212: ...194 IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide ...
Страница 217: ......
Страница 218: ... Part Number 42D2167 Printed in USA 1P P N 42D2167 ...