locrit
The low-temperature critical threshold.
hiwarn
The high-temperature warning threshold.
hicrit
The high-temperature critical threshold.
-a
Displays the ambient temperature of the enclosure and temperature threshold
statuses.
-f [fan] Displays the status of all the fans, or of only the specified fans. Valid values for
the [fan] parameter are: 1, 2, 3, and so on.
-d [drive_bay]
Displays the status of all the disk drive bays (slots), or of only the specified
disk drive bays. Valid values for the [drive_bay] parameter are: 1, 2, 3, and so
on.
-p [PSU]
Displays the status of all the power supply assemblies, or of only the specified
power supply assemblies. Valid values for the [PSU] parameter are 1, 2.
-o
Displays the status of the operator panel.
-c
Displays the status of the controller card.
-I ID[-U]
Modifies the enclosure ID. The ID must be a four-character alphanumeric
string. The optional -U flag causes the object data manager (ODM) to be
updated to show the change.
-B mode
Modifies all bypass cards to the given mode.
-B card=mode
Modifies the specified bypass cards to be in the given modes. The valid values
for the mode parameter are:
v
Automatic
v
Bypass
v
Inline
v
Open
Valid values for the card parameter are 1, 2, 3, 4, and so on.
-S
Resets the “exchanged” flag of the selected FRU.
-T threshold=value
Modifies the specified temperature thresholds to the given values. The valid
values for the [threshold] parameter are:
lowarn
The low-temperature warning threshold.
hiwarn
The high-temperature warning threshold.
The value parameter is a temperature in degrees C.
Appendix A. Operating with RISC Systems
83
Содержание 7133 D40
Страница 1: ...7133 Models D40 and T40 Serial Disk Systems Operator Guide SA33 3278 02 ...
Страница 2: ......
Страница 3: ...7133 Models D40 and T40 Serial Disk Systems Operator Guide SA33 3278 02 ...
Страница 10: ...viii 7133 Models D40 and T40 Operator Guide ...
Страница 12: ...x 7133 Models D40 and T40 Operator Guide ...
Страница 34: ...20 7133 Models D40 and T40 Operator Guide ...
Страница 44: ...b Push the lock up to the front of the disk drive module 30 7133 Models D40 and T40 Operator Guide ...
Страница 48: ...34 7133 Models D40 and T40 Operator Guide ...
Страница 66: ...3 Push the replacement fan assembly fully into the unit 52 7133 Models D40 and T40 Operator Guide ...
Страница 67: ...4 Tighten the captive bolt by turning the thumbscrew clockwise Chapter 4 Dealing with Problems 53 ...
Страница 76: ...6 Push the replacement power supply assembly fully into the unit 62 7133 Models D40 and T40 Operator Guide ...
Страница 78: ...8 Tighten the two captive bolts by turning the thumbscrews clockwise 64 7133 Models D40 and T40 Operator Guide ...
Страница 102: ...Command Line Tools Not applicable to PC servers 88 7133 Models D40 and T40 Operator Guide ...
Страница 105: ......
Страница 106: ...Part Number 34L3838 Printed in the U S A SA33 3278 02 34L3838 ...