The status light for this disk drive, at the front cover of the 7133 unit, shows
the same conditions as this light.
Check light
The Check light, which is amber, shows the following conditions:
Off
Normal operating condition
Permanently On
One of the following conditions exists:
v
An unrecoverable error that prevents the normal operation of the
SSA links to the disk drive has been detected.
v
Neither SSA link to the disk drive is active.
v
The power-on self-tests (POSTs) are running or have failed. The
light comes on as soon as the disk drive is switched on, and goes
off when the POSTs are completed successfully. If the light remains
on for longer than one minute after the disk drive is switched on,
the POSTs have failed.
v
The disk drive is in service mode, and can be removed from the
7133 unit.
Flashing
The Check light has been set by an SSA service aid to identify the
position of this disk drive module.
Fan Assembly Lights
Three fan assemblies are installed in the front of 7133 Models D40 and T40 units. To
see their lights:
v
For a Model D40, open the cover of the 7133 by pivoting it downward.
v
For a Model T40, open the front cover of the 7133 by:
1. If necessary, unlocking the cover using the key provided.
2. Gripping the front cover on the right and pivoting it to the left.
10
7133 Models D40 and T40 Operator Guide
Содержание 7133 D40
Страница 1: ...7133 Models D40 and T40 Serial Disk Systems Operator Guide SA33 3278 02 ...
Страница 2: ......
Страница 3: ...7133 Models D40 and T40 Serial Disk Systems Operator Guide SA33 3278 02 ...
Страница 10: ...viii 7133 Models D40 and T40 Operator Guide ...
Страница 12: ...x 7133 Models D40 and T40 Operator Guide ...
Страница 34: ...20 7133 Models D40 and T40 Operator Guide ...
Страница 44: ...b Push the lock up to the front of the disk drive module 30 7133 Models D40 and T40 Operator Guide ...
Страница 48: ...34 7133 Models D40 and T40 Operator Guide ...
Страница 66: ...3 Push the replacement fan assembly fully into the unit 52 7133 Models D40 and T40 Operator Guide ...
Страница 67: ...4 Tighten the captive bolt by turning the thumbscrew clockwise Chapter 4 Dealing with Problems 53 ...
Страница 76: ...6 Push the replacement power supply assembly fully into the unit 62 7133 Models D40 and T40 Operator Guide ...
Страница 78: ...8 Tighten the two captive bolts by turning the thumbscrews clockwise 64 7133 Models D40 and T40 Operator Guide ...
Страница 102: ...Command Line Tools Not applicable to PC servers 88 7133 Models D40 and T40 Operator Guide ...
Страница 105: ......
Страница 106: ...Part Number 34L3838 Printed in the U S A SA33 3278 02 34L3838 ...