Error Code/Symptom
FRU/Action
1803
(No more memory (above 1
MB for PCI adapter)
1. Run
Configuration/Setup
2. Failing Adapter
3. System Board
1804
(No more memory (below 1
MB for PCI adapter)
1. Run
Configuration/Setup
2. Move failing adapter to
slot 1 or 2
3. Failing Adapter
4. System Board
1805
(PCI option ROM checksum
error)
1. Remove Failing PCI
Card
2. System Board
1806
(PCI to PCI Bridge error)
1. Run
Configuration/Setup
2. Move failing adapter to
slot 1 or 2
3. Failing Adapter
4. System Board
2400
(Video controller test failure)
1. Video Adapter
(if installed)
2. System Board
2462
(Video memory
configuration error)
1. Video Adapter
(if installed)
2. System Board
8603
(Pointing Device Error)
1. Pointing Device
2. System Board
I9990301
(Fixed boot sector error, no
operating system installed)
1. Run
Configuration/Setup
for correct startup
2. Verify operating
system installed
I9990305
(Fixed boot sector error, no
operating system installed)
1. Install operating
system to hard disk
drive
114
PC Server HMM
Содержание 325 8639
Страница 97: ...Drawer Model Rails Drives 92 PC Server HMM ...
Страница 102: ...Operator Panel and Cable Note Loosen do not remove screw Screw PC Server 325 Type 8639 97 ...
Страница 108: ...System Board Note Note A black square indicates pin 1 PC Server 325 Type 8639 103 ...
Страница 120: ...Parts Listings 1 2 3 4 5 6 7 8 9 10 12 11 13 14 15 16 17 18 20 19 PC Server 325 Type 8639 115 ...
Страница 121: ...21 23 24 25 22 26 27 28 29 30 116 PC Server HMM ...
Страница 129: ...124 PC Server HMM ...
Страница 145: ...IBM Part Number 84H3049 Printed in U S A S84H 3ð49 ðð ...