Beep
code
Description
Action
3-3-3
No
operational
memory
in
system.
1.
Make
sure
that
the
server
contains
the
correct
number
of
DIMMs,
in
the
correct
order;
install
or
reseat
DIMMS;
then,
restart
the
server.
Important:
In
some
memory
configurations,
the
3-3-3
beep
code
might
sound
during
POST,
followed
by
a
blank
monitor
screen.
If
this
occurs
and
the
Boot
Fail
Count
option
in
the
Start
Options
of
the
Configuration/Setup
Utility
program
is
enabled,
you
must
restart
the
server
three
times
to
reset
the
configuration
settings
to
the
default
configuration
(the
memory
connector
or
bank
of
connectors
enabled).
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
DIMMs
b.
(Trained
service
technician
only)
System
board
64
IBM
xSeries
306m
Types
8849
and
8491:
Problem
Determination
and
Service
Guide
Содержание 306m - eServer xSeries - 8849
Страница 1: ...IBM xSeries 306m Types 8849 and 8491 Problem Determination and Service Guide ...
Страница 2: ......
Страница 3: ...IBM xSeries 306m Types 8849 and 8491 Problem Determination and Service Guide ...
Страница 8: ...vi IBM xSeries 306m Types 8849 and 8491 Problem Determination and Service Guide ...
Страница 143: ......
Страница 144: ... Part Number 31R1183 Printed in USA 1P P N 31R1183 ...