Symptom
Action
A
hard
disk
drive
passes
the
diagnostic
Fixed
Disk
Test
but
the
problem
remains.
Run
the
diagnostic
SCSI
Fixed
Disk
Test
(see
Note:
This
test
is
not
available
on
servers
that
have
RAID
arrays
or
servers
that
have
SATA
hard
disk
drives.
Use
the
Fixed
Disk
Test
for
SATA
hard
disk
drives
or
servers
that
have
RAID
arrays.
Intermittent
problems
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Symptom
Action
A
problem
occurs
only
occasionally
and
is
difficult
to
diagnose.
1.
Make
sure
that:
v
All
cables
and
cords
are
connected
securely
to
the
rear
of
the
server
and
attached
devices.
v
When
the
server
is
turned
on,
air
is
flowing
from
the
fan
grille.
If
there
is
no
airflow,
the
fan
is
not
working.
This
can
cause
the
server
to
overheat
and
shut
down.
2.
Check
the
system-error
log
(see
3.
See
Chapter
5.
Diagnostics
77
Содержание 306m - eServer xSeries - 8849
Страница 1: ...IBM xSeries 306m Types 8849 and 8491 Problem Determination and Service Guide ...
Страница 2: ......
Страница 3: ...IBM xSeries 306m Types 8849 and 8491 Problem Determination and Service Guide ...
Страница 8: ...vi IBM xSeries 306m Types 8849 and 8491 Problem Determination and Service Guide ...
Страница 143: ......
Страница 144: ... Part Number 31R1183 Printed in USA 1P P N 31R1183 ...