background image

 78

IBM® xSeries 150 : User’s Reference

 

 

1162

The serial port configuration conflicts with another device in the system.  

Action: 

1. Make sure the IRQ and I/O port assignments needed by the serial port are 

available. 

2. If all interrupts are being used by adapters, you might need to remove an 

adapter to make an interrupt available to the serial port, or force other adapters 
to share an interrupt.

1301

Cable to Information LED panel not detected.  

Action: 

Make sure that the cable to the operator information panel is connected.

If the problem persists, call for service.

1302

Cable to Power and Reset pushbuttons not detected.  

Action: 

Make sure that the cable to the Power and Reset pushbuttons is connected.

If the problem persists, call for service.

1303

I2C cable to Power Backplane not detected.  

Action: 

Make sure that the cable to the power backplane is connected.

If the problem persists, call for service.

1304

Cable to Diagnostic LED panel not detected.  

Action: 

Make sure that the cable to the diagnostic LED panel is connected.

If the problem persists, call for service.

1600

The Netfinity Advanced System Management processor is not functioning.  

Action: 

1. Verify that the jumpers for the system-management processor are set correctly. 

2. Disconnect the server from all electrical sources, wait for 30 seconds, reconnect 

the server to the electrical sources, and restart the server.

If the problem persists, call for service.

1601

The BIOS needs to be updated.  

Action: 

1. Disconnect the server from all electrical sources, wait for 30 seconds, reconnect 

the server to the electrical sources, and restart the server.

2. If the problem persists, update the BIOS.

If the problem persists, call for service.

1800

A PCI adapter has requested a hardware interrupt that is not available.  

Action: 

1. Make sure that the PCI adapter and all other adapters are set correctly in the 

Configuration/Setup Utility program. If the interrupt resource settings are not 
correct, change the settings.

2. If all interrupts are being used by other adapters, you might need to remove an 

adapter to make an interrupt available to the PCI adapter, or force other 
adapters to share an interrupt.

Table 12. POST error messages 

POST message

Description

Содержание 150

Страница 1: ...IBM IBM xSeries 150 User s Reference...

Страница 2: ......

Страница 3: ...IBM IBM xSeries 150 User s Reference...

Страница 4: ...ormation in Appendix B Product warranties and notices on page 143 First Edition October 2000 Copyright International Business Machines Corporation 2000 All rights reserved US Government Users Restrict...

Страница 5: ...kirjanen ennen kuin asennat t m n tuotteen Avant de proc der l installation de ce produit lisez le manuel Safety Information Vor Beginn der Installation die Brosch re mit Sicherheitshinweisen lesen Pr...

Страница 6: ...nstalar este produto leia o folheto Informa es sobre Seguran a Antes de instalar este producto lea la Informaci n de Seguridad L s s kerhetsinformationen innan du installerar den h r produkten Safety...

Страница 7: ...y equipment when there is evidence of fire water or structural damage Disconnect the attached power cords telecommunications systems networks and modems before you open the device covers unless instru...

Страница 8: ...uired by local ordinances or regulations Statement 3 CAUTION When laser products such as CD ROMs DVD drives fiber optic devices or transmitters are installed note the following Do not remove the cover...

Страница 9: ...ON The power control button on the device and the power switch on the power supply do not turn off the electrical current supplied to the device The device also might have more than one power cord To...

Страница 10: ...viii IBM xSeries 150 User s Reference...

Страница 11: ...the bezel 51 Connecting external options 53 Installation procedure 53 I O connector locations 53 Input Output ports 54 Parallel port 54 Viewing or changing the parallel port assignments 54 Parallel po...

Страница 12: ...ervices 135 Terminal Services Client 136 Appendix A Rack Installation Instructions 139 Appendix B Product warranties and notices 143 Warranty Statements 143 IBM Statement of Limited Warranty for Unite...

Страница 13: ...150 model and other IBM server products at the following World Wide Web address http www ibm com pc us netfinity Your server serial number and model number are located on labels on the rear of the ser...

Страница 14: ...60 mm 26 0 in Width 220 mm 8 7 in Weight approximately 36 74 Kg 81 lb when fully configured Integrated functions Netfinity Advanced System Management processor ServeRAID 4L 4H PCI adapter Dual channel...

Страница 15: ...wo Pentium III microprocessors Your server comes with one microprocessor installed you can install an additional microprocessor to enhance performance and provide SMP capability Large data storage and...

Страница 16: ...switching occurs without data loss and without user intervention Optional digital linear tape drive The addition of an optional digital linear tape drive DLT allows quick backup of large amounts of da...

Страница 17: ...5 Operator information panel Diagnostic LEDs on the system board Customer support center 24 hours per day 7 days a week1 1 Service availability will vary by country Response time will vary depending o...

Страница 18: ...r model Rack model Hard disk drive activity light green Hard disk drive status light amber Reset button Power control button Power control button shield if installed Cover release latch Serial number...

Страница 19: ...slowly one flash per second the drive is being rebuilt When the light flashes rapidly three flashes per second the controller is identifying the drive Operator information panel The following illustr...

Страница 20: ...en a system error occurs An LED on the diagnostic panel on the system board will also be on to further isolate the error Refer to the Problem solving section of the User s Reference on the IBM xSeries...

Страница 21: ...20 to 24 in and position it so you can view it without having to twist your body Also position other equipment you use regularly such as the telephone or a mouse within easy reach Glare and lighting P...

Страница 22: ...length of power cords and cables that connect to the monitor printer and other devices might determine the final placement of your server When arranging your workspace Avoid the use of extension cord...

Страница 23: ...onents This means that you can install or remove the component while the system is running provided that your system is configured to support this function For complete information about installing or...

Страница 24: ...rd System board options connectors The following illustration identifies system board connectors for user installable options Note The illustrations in this document might differ slightly from your ha...

Страница 25: ...MHz J44 PCI slot 4 64 bit 33 MHz J39 PCI slot 3 64 bit 33 MHz J34 PCI slot 2 32 bit 33 MHz J32 PCI slot 1 32 bit 33 MHz J27 Battery DIMM 1 J23 DIMM 2 J21 DIMM 3 J19 DIMM 4 J18 Microprocessor 2 U17 Mi...

Страница 26: ...connectors The following illustration identifies system board connectors for external devices Note The illustrations in this document might differ slightly from your hardware SCSI channel B J29 SCSI...

Страница 27: ...tration identifies the switches and jumpers on the system board Note The illustrations in this document might differ slightly from your hardware Parallel port J22 Video Advanced System Management Proc...

Страница 28: ...at the top of the switch block and switch 1 is at the bottom The Off position for each switch is the side nearer the diagnostics panel The following table describes the function for each switch Table...

Страница 29: ...fault setting is Off disabled When On overrides the power on switch and forces power on mode The system will always boot without the use of the power on switch 4 Reserved 3 Reserved 2 Reserved 1 Reser...

Страница 30: ...wer supply 3 failure NON Non redundant power OVER Overspec The system has exceeded the power capabilities of the installed power supply units NMI Non maskable interrupt occurred TEMP System temperatur...

Страница 31: ...t swap component see the information provided in this chapter The blue color on components and labels identifies touch points where a component can be gripped a latch moved and so on Make sure that yo...

Страница 32: ...st watches Remove items from your shirt pocket such as pens or pencils that could fall into the server as you lean over it Take care to avoid dropping any metallic objects such as paper clips hair pin...

Страница 33: ...zioni sulla sicurezza Lees voordat u dit product installeert eerst het boekje met veiligheidsvoorschriften Les heftet om sikkerhetsinformasjon Safety Information f r du installerer dette produktet Ant...

Страница 34: ...alar este producto lea la Informaci n de Seguridad L s s kerhetsinformationen innan du installerar den h r produkten Preden namestite ta izdelek preberite knji ico Varnostne informacije Install l s el...

Страница 35: ...ever turn on any equipment when there is evidence of fire water or structural damage Disconnect the attached power cords telecommunications systems networks and modems before you open the device cover...

Страница 36: ...uired by local ordinances or regulations Statement 3 CAUTION When laser products such as CD ROMs DVD drives fiber optic devices or transmitters are installed note the following Do not remove the cover...

Страница 37: ...tement 5 CAUTION The power control button on the device and the power switch on the power supply do not turn off the electrical current supplied to the device The device also might have more than one...

Страница 38: ...2 If you are planning to install or remove any part other than a hot swap hard disk drive or hot swap power supply turn off the server and all attached devices and disconnect all external cables and p...

Страница 39: ...es and disconnect all external cables and power cords 3 Release the left and right side latches and pull the server out of the rack enclosure until both slide rails lock Note When the server is in the...

Страница 40: ...ate the flange on the top edge of the door 3 Press down on the flange while pressing out on the door then lift the server door up and off the hinge Set the door aside in a safe place To remove the bez...

Страница 41: ...th adapters You can install up to five peripheral component interconnect PCI adapters in the expansion connectors called slots on the system board of your server Your server comes with an integrated v...

Страница 42: ...t support 3 3V adapters You might require additional power supplies if adapters are added that have electrical current requirements that exceed the installed power supply capabilities Your server uses...

Страница 43: ...emove the cover See Removing the cover door and bezel on page 26 for details 3 Determine which expansion slot you will use for the adapter Note Check the instructions that come with the adapter for an...

Страница 44: ...e you apply power Incomplete insertion might cause damage to the system board or the adapter d Replace the retaining clip on the adapter support bracket if you opened it e Align the bottom tabs of the...

Страница 45: ...ng illustrations Attention If you are going to install additional drives in the non hot swap bays you must install the power supply backplane option and additional power supplies Note The illustration...

Страница 46: ...ve or install a non hot swap drive you must turn off the server first Non hot swap drives are installed in bays A B C and D only Your server comes with a preinstalled 3 5 inch 1 44 MB diskette drive i...

Страница 47: ...the drive go to Installing a hot swap drive or to Installing a non hot swap drive on page 38 as appropriate Installing a hot swap drive Note The illustrations in this document might differ slightly fr...

Страница 48: ...s being rebuilt When the green light flashes rapidly three flashes per second the controller is identifying the drive Note If your server has a RAID adapter installed refer to the information provided...

Страница 49: ...all the hard disk drive in the hot swap bay a Ensure the tray handle is open that is perpendicular to the drive b Align the rails on the drive assembly with the guide rails in the drive bay c Gently p...

Страница 50: ...over and the bezel see Removing the cover door and bezel on page 26 for details 3 Remove the filler panel from the bay opening by pulling the filler panel away from the server You do not need the fill...

Страница 51: ...of the IDE cable is plugged into the IDE connector on the system board Go to step 12 11 If the drive is a SCSI device a Make sure the drive is not a hard disk drive b Obtain a 16 bit SCSI cable to con...

Страница 52: ...with your server 3 Installing or removing DIMMs changes the configuration information in the server Therefore after installing or removing a DIMM you must save the new configuration information by usi...

Страница 53: ...rs This enhances performance for database and point of sale applications integrated manufacturing solutions and other applications Notes 1 Before you install a new microprocessor review the documentat...

Страница 54: ...it again if you ever remove the microprocessor and do not replace the microprocessor 4 Install the microprocessor a Touch the static protective package containing the new microprocessor to any unpain...

Страница 55: ...ardware Filler panels To maintain proper airflow keep filler panels in place on empty power supply bays Power supply bay 1 If you install an optional power supply in this bay LED PS1 on the system boa...

Страница 56: ...ply which gives redundancy and will make the power supplies hot swappable You can also add a third power supply for additional capacity After you install a power supply verify that the power supply st...

Страница 57: ...rd into a properly grounded electrical outlet 6 Verify that the DC Power light and AC Power light on the power supply are lit indicating that the power supply is operating correctly 7 If you have othe...

Страница 58: ...s of the operator information panel b If the NON LED is not lit you have redundancy and do not need to turn off the server Continue with step 2 Note The illustrations in this document might differ sli...

Страница 59: ...rations in this document might differ slightly from your hardware To replace the fan assembly 1 Review the safety precautions listed in Statement 1 and Statement 5 in Safety information on page 20 2 T...

Страница 60: ...ser s Reference 8 Verify that the FAN LED on the diagnostic panel is not lit If the FAN LED is lit reseat the fan 9 If you have other options to install or remove do so now otherwise go to Installing...

Страница 61: ...differ slightly from your hardware To install the server left side cover 1 Align the cover with the left side of the server about 25mm 1inch from the front of the server place the bottom of the cover...

Страница 62: ...2 Press the top of the bezel toward the server until it clicks into place To install the server door 1 Set the door on the bottom hinge 2 Press the flange downward while pressing the top of the door t...

Страница 63: ...server about 25mm 1inch from the front of the server the flanges on the left and right sides of the cover should be on the outside of the server chassis 2 Hold the cover against the server and slide t...

Страница 64: ...er s Reference To install the bezel 1 Place the tabs on the left side of the bezel in the slots at the left front of the server 2 Press the right end of the bezel toward the server until the bezel cli...

Страница 65: ...erver Note If you are attaching a SCSI device see SCSI ports on page 59 for SCSI ID and cabling information I O connector locations The following illustration shows the input output connectors ports a...

Страница 66: ...d from and written to a device In bidirectional mode the server supports the ECP and EPP modes To view or change the parallel port assignment 1 Restart the server and watch the monitor screen 2 When t...

Страница 67: ...t certain communication port addresses You might need to use the Table 3 Parallel port connector pin number assignments Pin I O SPP ECP Signal EPP Signal 1 O STROBE WRITE 2 I O Data 0 Data 0 3 I O Dat...

Страница 68: ...he following table shows the pin number assignments for the 9 pin male D shell serial port connectors on the rear of your server These pin number assignments conform to the industry standard Universal...

Страница 69: ...erver for attaching USB compatible devices The following table shows the pin number assignments for the USB port connectors on the rear of your server Keyboard port There is one keyboard port on the r...

Страница 70: ...ter Note If you install a PCI video adapter the server BIOS will automatically disable the integrated video controller The following table shows the pin number assignments for the 15 pin analog video...

Страница 71: ...an internal channel connector on the RAID adapter SCSI cabling requirements If you plan to attach external SCSI devices you must order additional SCSI cables To select and order the correct cables for...

Страница 72: ...11 Data 5 45 Data 5 12 Data 6 46 Data 6 13 Data 7 47 Data 7 14 Data P 48 Data P 15 Ground 49 Ground 16 DIFFSENS 50 Ground 17 Term power 51 Term power 18 Term power 52 Term power 19 Reserved 53 Reserv...

Страница 73: ...thernet controller However you must install a device driver to enable your operating system to address the Ethernet controller The device drivers are provided on the ServerGuide CDs Failover for redun...

Страница 74: ...ent Viewer log IntraNetWare 1 Add the redundant NIC adapter according to the instructions that are provided with the adapter 2 Load the device driver by using the following command LOAD d path PCNTNW...

Страница 75: ...e RS 485 function enables you to connect the Advanced System Management Processors of several rack mounted servers so that they can communicate with each other in half duplex mode Note When using the...

Страница 76: ...64 IBM xSeries 150 User s Reference Additionally for rack models be sure to route the cables through the cable management assembly on the rack see page 65 Cable restraint bracket...

Страница 77: ...Chapter 3 Installing Options 65 Routing cables through cable management assembly Note The illustrations in this document might differ slightly from your hardware Cable straps...

Страница 78: ...66 IBM xSeries 150 User s Reference...

Страница 79: ...s to indicate successful test completion or the detection of a problem See POST on page 70 for more information Light path diagnostics Your server has light emitting diodes LEDs to help you identify p...

Страница 80: ...r s Reference forum For more detailed information about registering and creating a customized profile for your IBM products visit the following addresses on the Web http www ibm com pc register http w...

Страница 81: ...r Use the troubleshooting information provided with your server to determine the cause of the problem and the action to take Flash the latest levels of BIOS service processor diagnostics and RAID code...

Страница 82: ...another pause and four more consecutive beeps The possible types of beep codes that your server might emit include the following No beeps If no beep occurs after your server completes POST that is aft...

Страница 83: ...ll for service If you are using an optional video adapter replace the failing video adapter One long and two short beeps A video I O adapter ROM is not readable or the video subsystem is defective If...

Страница 84: ...has failed 2 2 2 Keyboard controller test has failed 2 2 3 CMOS power failure and checksum checks have failed 2 2 4 CMOS configuration information validation has failed Call for service 2 3 2 Screen m...

Страница 85: ...microprocessor test Action Call for service 114 An adapter read only memory ROM error occurred Action Remove the options If you can start the server without the options installed reinstall each optio...

Страница 86: ...device is failing and is no longer recognized by the server as being installed An external device is not turned on An invalid checksum is detected in the battery backed memory Action Verify that all...

Страница 87: ...If the problem persists call for service 175 A vital product data VPD error occurred Action Call for service 176 177 178 A security hardware error occurred Action Check for indications that someone h...

Страница 88: ...the L2 cache of one of the microprocessors Action 1 If you just installed a microprocessor verify that the microprocessor is installed and seated correctly 2 If the problem persists check to see if th...

Страница 89: ...eflects the type of diskette drive that you have installed 2 Run the diagnostic tests If the diagnostic tests fail call for service 662 A diskette drive configuration error occurred Action If you remo...

Страница 90: ...LED panel is connected If the problem persists call for service 1600 The Netfinity Advanced System Management processor is not functioning Action 1 Verify that the jumpers for the system management pr...

Страница 91: ...itor is connected correctly to the video connector If the monitor is connected correctly call for service 2462 A video memory configuration error occurred Action Make sure that the monitor cables are...

Страница 92: ...Configuration Setup Utility program If the memory resource settings are not correct change the settings 2 If all memory resources are being used you might need to remove an adapter to make memory avai...

Страница 93: ...device ID Action Call for service 00180800 An unsupported PCI device is installed Action Remove the PCI adapters If you can start the server without the adapters reinstall each adapter one at a time a...

Страница 94: ...298200 Microprocessor speed mismatch Action The microprocessors installed do not run at the same speed install microprocessors with identical speeds I9990301 A hard disk drive error occurred Action Ca...

Страница 95: ...the three digit function code that indicates the function being tested when the error occurred For example function code 089 is for the microprocessor ttt is the three digit failure code that indicate...

Страница 96: ...agnostic test before it is complete Not Applicable This result occurs when you specify a diagnostic test for a device that is not present Aborted This result occurs when the test could not proceed bec...

Страница 97: ...such as system configuration memory contents interrupt request IRQ use direct memory access DMA use device drivers and so on by selecting Hardware Info from the top of the screen When the tests have...

Страница 98: ...keyboard or mouse attached you cannot run the diagnostic program for the USB interface 1 Turn off the server 2 Replace the USB keyboard and mouse with a standard keyboard and mouse 3 Turn on the serve...

Страница 99: ...the ServeRAID Configuration Utility If the problem persists call for service On system board adapter drive configuration error Logical drive on system board adapter Adapter in slot n memory allocation...

Страница 100: ...or in socket id xyz is installed but not functioning where xyz identifies the microprocessor that is causing the error message Microprocessor in socket id xyz where xyz identifies the microprocessor t...

Страница 101: ...call for service VRM corresponding to Microprocessor in socket id xyz is not installed where xyz identifies the microprocessor whose VRM is causing the error message Install a VRM If the problem persi...

Страница 102: ...MM 2 If the problem remains replace the DIMM If the problem persists call for service Test setup error Corrupt BIOS in ROM If your server does not have the latest level BIOS installed update the BIOS...

Страница 103: ...microprocessor in socket id xyz where xyz identifies the microprocessor that is causing the error message Failed Microprocessor in socket ID xyz where xyz identifies the microprocessor that is causin...

Страница 104: ...where n is the number of the device and m is the adapter number The unload eject push button test failed for device n on adapter m where n is the number of the device and m is the adapter number The...

Страница 105: ...modem If the problem persists call for service PCI modem detected but not enabled 1 Change the configuration to enable the modem 2 If the problem remains replace the modem If the problem persists cal...

Страница 106: ...ot be overwritten The recovery boot block is a section of code in this protected area that enables the server to start up and to read a flash diskette The flash utility recovers the system BIOS from t...

Страница 107: ...ower supplies will be on Use the light path diagnostics to identify the type of error that occurred Light path diagnostics You can use the light path diagnostics built into your server to quickly iden...

Страница 108: ...power problem Possible causes 1 The Power Control button on the front of the server is in the Off position Action Press the Power Control button to start the server 2 The power supply has failed Acti...

Страница 109: ...d PS1 Power supply 1 has failed Replace power supply 1 PS2 Power supply 2 has failed Replace power supply 2 PS3 Power supply 3 has failed Replace power supply 3 NON Power supply redundancy has been lo...

Страница 110: ...processors has failed or a microprocessor is installed in the wrong connector 1 Check the microprocessor failure LEDs on the system board 2 If a microprocessor failure LED is on make sure the micropro...

Страница 111: ...on the system board If the VRM1 Failure LED is on have the system serviced If the VRM2 Failure LED is on 1 Turn off the server reseat the VRM and restart the server 2 If the problem persists replace...

Страница 112: ...for the CD ROM drive CD ROM drive is not recognized Diskette drive If there is a diskette in the drive verify that 1 The diskette drive is enabled in the Configuration Setup Utility program 2 The dis...

Страница 113: ...Memory problems Verify that 1 The memory modules are seated properly 2 You have installed the correct type of memory 3 If you changed the memory you updated the memory configuration with the Configura...

Страница 114: ...hen move the device and the monitor at least 305 mm 12 in apart Turn on the monitor Notes 1 To prevent diskette drive read write errors be sure the distance between monitors and diskette drives is at...

Страница 115: ...power cables are properly connected to the server 2 The electrical outlet functions properly 3 The type of memory installed is correct 4 If you just installed an option remove it and restart the serv...

Страница 116: ...d is not available for use by the operating system This port does not appear in the Configuration Setup Utility program menus it can be configured using Netfinity Manager If the problem still exists c...

Страница 117: ...se from the hub If the light is off there might be a bad connector or cable or a problem with the hub The Ethernet Transmit Receive Activity light illuminates when the Ethernet controller sends or rec...

Страница 118: ...r service Ethernet Link Status light does not light Check the following Make sure that the hub is turned on Check all connections at the Ethernet controller and the hub Check the cable A crossover cab...

Страница 119: ...well when they share an interrupt with a dissimilar PCI device Try changing the IRQ assigned to the Ethernet adapter or the other device If the problem remains call for service The Ethernet controller...

Страница 120: ...some memory resources in the server Then restart the server PCNTNW NW 074 The hardware interrupt cannot be set Explanation An attempt was made to initialize a given hardware interrupt The attempt was...

Страница 121: ...ction None necessary message is for information only PCNTNW NW 164 The device was not found Explanation The driver cannot find an Ethernet controller in the server Action Verify that the Ethernet cont...

Страница 122: ...y that the Ethernet controller is enabled If the Ethernet controller is enabled go to Starting the diagnostic programs on page 84 to run the diagnostic programs PCNTND 21 The adapter failed the checks...

Страница 123: ...the primary Ethernet connection and has transferred all network traffic to the secondary Ethernet controller Action Identify the cause of the failure on the primary Ethernet connection Restoring the...

Страница 124: ...ists run the diagnostic programs pnt0 17 Device fault Reset initiated Explanation The SunSoft Solaris driver has been reset due to a device fault Action Verify that additional IBM Netfinity 10 100 Fau...

Страница 125: ...onfigure your server and reset the system date and time pnt0 23 add_intr_handler failed Vector already occupied Explanation The interrupt request IRQ that was specified or the IRQ that was found confl...

Страница 126: ...tery clip d Ensure that the battery clip is touching the base of the battery socket by pressing gently on the clip 4 Insert the new battery a Tilt the battery so that you can insert it into the socket...

Страница 127: ...information and download device drivers and updates Some of these pages are You can select a country specific Web site from these pages You might also want to visit the Web pages of other companies f...

Страница 128: ...with determining if you have a hardware problem and deciding what action is necessary to fix the problem IBM hardware repair If the problem is determined to be caused by IBM hardware under warranty t...

Страница 129: ...oting information in your hardware documentation or run the diagnostic tests If you suspect a software problem consult the documentation including README files for the operating system or application...

Страница 130: ...M Getting information by fax If you have a touch tone telephone and access to a fax machine in the U S and Canada you can receive by fax marketing and technical information on many topics including ha...

Страница 131: ...se have the following information ready when you call Machine Type and Model Serial numbers of your computer monitor and other components or your proof of purchase Description of the problem Exact wor...

Страница 132: ...s and custom installations Service availability and name might vary by country Enhanced PC support line Enhanced PC Support is available for desktop and mobile IBM computers that are not connected to...

Страница 133: ...contract with a 10 incident limit For more information about purchasing Network and Server Support see Ordering support line services Ordering support line services Enhanced PC Support Line and Netwo...

Страница 134: ...iety of post warranty maintenance options including ThinkPad EasyServ Maintenance Agreements Availability of the services varies by product For more information about warranty upgrades and extensions...

Страница 135: ...rtable CD that contains the preload image for your xSeries 150 and is used to recover the preloaded image on your server You must start your server using the Recovery Enablement Diskette before you wi...

Страница 136: ...g your system with the ServeRAID Configuration Reset diskette will reset your ServeRAID adapter to factory default settings All data stored in your ServeRAID array will be lost Use this diskette only...

Страница 137: ...this CD Terminal Services Client The stand alone Win32 Terminal Services Client application The NAS appliance supports web based terminal services so this is an optional installation To install the Te...

Страница 138: ...126 IBM xSeries 150 User s Reference...

Страница 139: ...ge the appliance s network configuration including assigning the IP address default gateway network mask and DNS server to be used by the appliance You can also use the Advanced Appliance Configuratio...

Страница 140: ...rnet Explorer 4 01 or later Notes 1 If you are using Internet Explorer 5 x you must install the optional Java Virtual Machine VM support to access a client system running UM Services 2 If you are usin...

Страница 141: ...OK to log in Once you have logged in you can begin using Terminal Services Cleint to configure and manage your appliance Note To ensure system security use Windows Powered to change the Administrator...

Страница 142: ...ber type of appliance and whether DHCP in use by the appliance or not Furthermore it will report the hostname primary IP address subnet mask primary DNS address and primary gateway address if these ar...

Страница 143: ...at appears in the Information Pane varies depending on the item that is selected For example if you select the All Appliances item from the Tree View Pane the Information Pane displays configuration i...

Страница 144: ...ly categorize discovered appliances and to configure them with the appropriate network settings Family rules are defined solely by appliance type or purpose Each Family can contain only one type of ap...

Страница 145: ...erefore the order in which Families appear is important To adjust this search order right click on a Family and then select Move Up or Move Down to adjust its position within the Families list Orphane...

Страница 146: ...ll be used by appliances that are members of this Family Default Gateway The IP address of the default gateway that will be used by appliances that are members of this Family optional DNS The IP addre...

Страница 147: ...he orphaned appliance and select Adopt by First Matching Family to move the appliance from the OrphanedExternally ConfiguredAppliances group to the newly createdFamily Move an appliance from one Famil...

Страница 148: ...ram 4 Accept the defaults in each window that opens or refer to the Microsoft Windows documentation for more instructions When the Terminal Services Client Setup program is completed proceed to the ne...

Страница 149: ...ou log on to Window Terminal Services you can view the Web Hosting Appliance graphical user interface GUI that is used to administer the appliance However when you first log onto Terminal Services the...

Страница 150: ...138 IBM xSeries 150 User s Reference...

Страница 151: ...uts when installing your server in a rack NOTE TO PRINTER Final Size 5 X 9 Colors Black Rack Mounting Template REAR Rack Mounting Template FRONT P N 09N8206 Printed in the U S A Slide rail Rear Left S...

Страница 152: ...o prevent the rack from overloading the power outlets when you install multiple devices in a rack The following is a list of items shipped in your rack installation kit If any items are missing or dam...

Страница 153: ...rail A 6 A A 3 A 5 B A Fully extend the slide rails out of the rack Lift the server above the rails then rest the rack support wheels located on the rear of the server on the slide rails Lower the fro...

Страница 154: ...your server documentation to complete the installation Store these instructions in the binder that comes with your server Route all the cables through the cable management assembly as shown Then use t...

Страница 155: ...s you purchase for your use and not for resale from IBM or your reseller The term Machine means an IBM machine its features conversions upgrades elements or accessories or any combination of them The...

Страница 156: ...ONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF EXPRESS OR IMPLIED WARRANTIES SO THE ABOVE EXCLUSION OR LIMITATION MAY NOT APPLY TO YOU IN THAT EVENT SUCH WARRANTIES ARE LIMITED IN DURATION TO THE WAR...

Страница 157: ...to fulfill their obligations and d inform IBM or your reseller of changes in a Machine s location IBM is responsible for loss of or damage to your Machine while it is 1 in IBM s possession or 2 in tr...

Страница 158: ...installed subsequently or otherwise Unless IBM specifies otherwise the following warranties apply only in the country where you acquire the Machine Nothing in this Statement of Warranty affects any st...

Страница 159: ...n will be provided WITHOUT WARRANTIES OF ANY KIND Warranty Service To obtain warranty service for the Machine contact your reseller or IBM You may be required to present proof of purchase IBM or your...

Страница 160: ...may not be new and may have been previously installed Regardless of the Machine s production status IBM s appropriate warranty terms apply Limitation of Liability Circumstances may arise where becaus...

Страница 161: ...y the Trade Practices Act 1974 IBM s liability is limited to the repair or replacement of the goods or the supply of equivalent goods Where that condition or warranty relates to right to sell quiet po...

Страница 162: ...ania Armenia Belarus Bosnia and Herzegovina Bulgaria Croatia Czech Republic Georgia Hungary Kazakhstan Kirghizia Federal Republic of Yugoslavia Former Yugoslav Republic of Macedonia FYROM Moldova Pola...

Страница 163: ...ddition to new parts re used parts as well Limitation of Liability The following is added to this Section The limitations and exclusions specified in the Statement of Warranty will not apply to damage...

Страница 164: ...ed 3 indirect damages even if IBM or your reseller is informed of their possibility SOUTH AFRICA NAMIBIA BOTSWANA LESOTHO AND SWAZILAND Limitation of Liability The following is added to this Section I...

Страница 165: ...duct is included as part of the Product Any software provided along with the Product that is associated with a separate end user license agreement is licensed to you under the terms of that license ag...

Страница 166: ...You must acquire a separate CAL for each electronic device that accesses or makes use of Authentication Services d Deploying CALs You may deploy CALs for the Product only in Per Seat mode In Per Seat...

Страница 167: ...ENVIRONMENTAL DAMAGE 6 TERMINATION Without prejudice to any other rights Manufacturer and or MS may cancel this EULA if you do not abide by the terms and conditions of this EULA in which case you mus...

Страница 168: ...LAR JURISDICTION PLEASE REFER TO THE WARRANTIES INCLUDED BELOW OR PROVIDED WITH THE SOFTWARE PRODUCT PRINTED MATERIALS End User License Agreement Microsoft Windows Services for NetWare Version 5 0 IMP...

Страница 169: ...oftware on other computers or unique electronic devices Devices may require additional licenses please consult the license agreement accompanying such software e Reservation of Rights Manufacturer and...

Страница 170: ...ou purchase the COMPUTER from Manufacturer 12 EXPORT RESTRICTIONS You acknowledge that the Product is subject to U S export jurisdiction You agree to comply with all applicable international and natio...

Страница 171: ...s is at your own risk Edition Notice INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE...

Страница 172: ...ry This IBM PC product cannot prevent errors that might occur if software you use or exchange data with is not ready for the Year 2000 IBM software that comes with this product is Year 2000 Ready Howe...

Страница 173: ...ands for 1000000000 bytes Total user accessible capacity may vary depending on operating environments Maximum internal hard disk drive capacities assume the replacement of any standard hard disk drive...

Страница 174: ...ipment standard entitled Digital Apparatus ICES 003 of the Department of Communications Avis de conformit aux normes du minist re des Communications du Canada Cet appareil num rique respecte les limit...

Страница 175: ...ord set consisting of a minimum 18 AWG Type SVT or SJT three conductor cord a maximum of 15 feet in length and a parallel blade grounding type attachment plug rated 15 amperes 125 volts For units inte...

Страница 176: ...eden Syria Togo Tunisia Turkey former USSR Vietnam former Yugoslavia Zaire Zimbabwe 13F9997 Denmark 14F0015 Bangladesh Burma Pakistan South Africa Sri Lanka 14F0033 Antigua Bahrain Brunei Channel Isla...

Страница 177: ...panel 8 18 front of server 6 lights See LEDs 6 logs error 67 82 event 67 82 M major components 11 memory configuration changes 40 specifications 2 memory module installing 40 order of installation 40...

Страница 178: ...166 IBM xSeries 150 User s Reference VRM See voltage regulator module 42 Y year 2000 readiness and instructions 160...

Страница 179: ......

Страница 180: ...IBM Part Number 25P2532 Printed in the United States of America on recycled paper containing 10 recovered post consumer fiber 25P2532 0425P2532...

Отзывы: