IBM® xSeries 150 : User’s Reference
The screen is blank.
Verify that:
1. The server power cord is plugged into the server and a working electrical outlet.
2. The monitor cables are connected properly.
3. The monitor is turned on and the Brightness and Contrast controls are adjusted
correctly.
If the items above are correct and the screen remains blank, call for service.
Only the cursor appears.
Call for service.
The monitor works when you
turn on the server, but goes
blank when you start some
application programs.
Verify that:
1. The primary monitor cable is connected to the video port.
2. You installed the necessary device drivers for the applications.
If the items above are correct and the screen remains blank, call for service.
Wavy, unreadable, rolling,
distorted screen, or screen jitter.
If the monitor self-tests show the monitor is OK, consider the location of the monitor.
Magnetic fields around other devices (such as transformers, appliances, fluorescent
lights, and other monitors) can cause screen jitter or wavy, unreadable, rolling, or
distorted screen images. If this happens, turn off the monitor. (Moving a color
monitor while it is turned on might cause screen discoloration.) Then move the
device and the monitor at least 305 mm (12 in.) apart. Turn on the monitor.
Notes:
1. To prevent diskette drive read/write errors, be sure the distance between
monitors and diskette drives is at least 76 mm (3 in.).
2. Non-IBM monitor cables might cause unpredictable problems.
3. An enhanced monitor cable with additional shielding is available for the 9521
and 9527 monitors. For information about the enhanced monitor cable, see your
IBM reseller or IBM marketing representative.
If the problem remains, call for service.
Wrong characters appear on the
screen.
If the wrong language is displayed, update the BIOS with the correct language.
If the problem remains, call for service.
Option problems
Verify that:
1. The option is designed for the server. Refer to the "Support for Netfinity Servers"
flowchart for information about obtaining ServerProven™ compatibility
information from the World Wide Web.
2. You followed the installation instructions that came with the option.
3. The option is installed correctly.
4. You have not loosened any other installed options or cables.
5. You updated the configuration information in the Configuration/Setup Utility
program. Whenever memory or an option is changed, you must update the
configuration.
If the problem remains, call for service.
An IBM option that was just
installed does not work.
Table 16. Troubleshooting charts
Device
Suggested action
Содержание 150
Страница 1: ...IBM IBM xSeries 150 User s Reference...
Страница 2: ......
Страница 3: ...IBM IBM xSeries 150 User s Reference...
Страница 10: ...viii IBM xSeries 150 User s Reference...
Страница 78: ...66 IBM xSeries 150 User s Reference...
Страница 138: ...126 IBM xSeries 150 User s Reference...
Страница 150: ...138 IBM xSeries 150 User s Reference...
Страница 178: ...166 IBM xSeries 150 User s Reference VRM See voltage regulator module 42 Y year 2000 readiness and instructions 160...
Страница 179: ......