114
IBM® xSeries 150 : User’s Reference
To replace the battery:
1. Read “Before you begin” on page 19, and follow any special handling and
installation instructions supplied with the replacement battery.
2. Turn off the server and peripheral devices and disconnect all external cables and
power cords; then, remove the server cover.
3. Remove the battery:
a. Use one finger to lift the battery clip over the battery.
b. Use one finger to slightly slide the battery out from its socket. The spring
mechanism will push the battery out toward you as you slide it from the
socket.
c. Use your thumb and index finger to pull the battery from under the battery
clip.
d. Ensure that the battery clip is touching the base of the battery socket by
pressing gently on the clip.
4. Insert the new battery:
a. Tilt the battery so that you can insert it into the socket, under the battery clip.
b. As you slide it under the battery clip, press the battery down into the socket.
Statement 2
CAUTION:
When replacing the lithium battery, use only IBM Part Number 33F8354 or an equivalent
type battery recommended by the manufacturer. If your system has a module containing a
lithium battery, replace it only with the same module type made by the same manufacturer.
The battery contains lithium and can explode if not properly used, handled, or disposed
of.
Do not:
•
Throw or immerse into water.
•
Heat to more than 100 C (212 F)
•
Repair or disassemble
Dispose of the battery as required by local ordinances or regulations.
Содержание 150
Страница 1: ...IBM IBM xSeries 150 User s Reference...
Страница 2: ......
Страница 3: ...IBM IBM xSeries 150 User s Reference...
Страница 10: ...viii IBM xSeries 150 User s Reference...
Страница 78: ...66 IBM xSeries 150 User s Reference...
Страница 138: ...126 IBM xSeries 150 User s Reference...
Страница 150: ...138 IBM xSeries 150 User s Reference...
Страница 178: ...166 IBM xSeries 150 User s Reference VRM See voltage regulator module 42 Y year 2000 readiness and instructions 160...
Страница 179: ......