3
©Copyright Lotronic 2013
Before using the DMX512 controller, you should set the channel address.
It
can be set between 001~511. Every binary address switch has a digital no.
Please refer to
:
No.
Digital No.
No.
Digital No.
1st
1
6th
32
2nd
2
7th
64
3rd
4
8th
128
4th
8
9th
256
5th
16
10th
Function switch
DMX Control Parameter Chart
Channel No
DMX512
fig.
Content
Channel 1
Control
mode
0~69
Shut off
70~139
Sound control
140~209
Auto play
210~255
manual
Channel
2
Pattern
Selection
0~33
Static pattern
34~255
Dynamic Geometric
pattern
Channel
3
Strobe
0-255
8 grade speed
0-255)/30=0-8do
Channel
4
Spot and
line
0-255
From line to spot effect
Channel
5
Horizontal
move
1~160
Manual
161~190
From left to right move
191-220
From right to left move
221-255
Right and left in-phase
move
Channel
6
1~160
Manual
161~190
From down to up
Vertical
move
191~220
From up to down
221~255
Up and down in-phase
move
Channel
7
Zoom(+/-)
pattern size
0-255
pattern size change
Channel
8
Color
selection
0-255
Channel
9
Reset
0-255
If the number exceeds
200, the unit will reset
Channel
10
Gradually
paint
0-255
Gradually paint
Warning
Power off before installation or maintenance.
LASER RADIATION !
DANGEROUS EXPOSURE TO LASER RADIATION
CLASS 3B LASER
ONLY FOR PROFESSIONAL USE
Maintenance
☆
Please clean the lens regularly. Do not do it using the wet cloth or other
chemical. The cleaning frequency depends on the using frequency and
surrounding conditions. It is recommended to clean the unit every 3
weeks.
☆
Please clean the lighting surface and engine outlet regularly.
☆
Be sure that there is no flammable or explosive subject nearby. The
least distance is 0.5 meters. at the same time, keep more than 15cm
between the wall and laser lighting;
Electric products must not be put into household waste. Please bring them to a
recycling centre. Ask your local authorities or your dealer about the way to
proceed.