27
ENG
20
5.6.
Filtration
This serves the function of filtering the water that is drawn through the filter. The
water then flows through the disinfectant (ozone or U.V.) and is reheated without
needing to be drained and refilled, thanks to the heat exchanger.
The filtration cycle has 2 stages:
1.
The massage pumps are turned on for 1 minute.
2.
The filtration pump is turned on for the set period.
When the filtration cycle is active, “FLt” is displayed on the control panel, alternating
with the water temperature.
Filtration is stopped if another function is activated, and it resumes 5 minutes after
the other function has been disabled.
The
filtration cycle
is programmed by setting the duration and the activation time
parameters as follows:
•
Duration:
from 0 - 12 h, in 1-hour increments, so 0 disables the function and 12 =
continuous filtration. By default, it is set at 0 hours (disabled).
•
Activation time:
enter the number of hours of delay before the function is required
to start. Selectable values from 0 (filtration starts immediately) to 12 hours, in 1-hour
increments. By default = 2 hours.
Once programmed, the cycles start every 12 hours, for the time entered with the
buttons, i.e., 2 filtration cycles per day, one every 12 hours, from the moment it is
first activated.
L2 sensors
L1 sensors
Sensors hidden
inside the shell