6.1.10.
For Electric/Key Start Machines insert the key in
to the ignition and turn the key Clockwise to the "ON"
position.
6.1.11.
Then turn the key 1 (one) turn further in a
clockwise position to the "START" position.
This will engage the starter motor and this will start the
generator.
NOTE:
If you are starting the generator for the first time we
recommend that you use the recoil starter.
CAUTION:
Do not attempt to run the starter motor for more than 5 seconds continuously. If the
generator engine fails to start, return the key to the "ON" position and wait about 10
seconds before attempting to start it again. Do not turn the key switch to the "START”
position when the generator engine is running as this could damage the starter motor.
When attempting to start the generator engine using the recoil starter ensure that the
key is in the "ON" position before pulling the recoil starter handle.
6.1.12.
After the engine has started, please return the
choke lever to the "OPEN” position.
For the IB-G3500 generator models, please refer to
Figure 2.
6.1.13.
Always let the generator engine warm up
sufficiently.
Figure 1
OPEN
CHOKE LEVER
CLOSE
Figure 2
OPEN
CLOSE
CHOKE LEVER
OFF
ON
ST
ART