background image

AST0922-940

Page 

19

Distributor Tube Length …………………………………………... 1 1/4 in (31.8mm) higher than top of mineral
tank
Standard Manifold Connection ……………………… 3/4 in NPT inlet-outlet, 1/2 in NPT drain in NORYL
manifold,
                                                                                                                            3/8 in NPT drain in brass
manifold
Optional Manifold Connections …………… 1 in NPT inlet-outlet, 1/2 in NPT drain; 3/4 in BSPT inlet-outlet, 3/8
in
                                                                                             BSPT drain; 1 in BSPT inlet-outlet, 1/2 in. BSPT
drain
Optional Bypass Valve ……………….. 3/4 in (19.1mm) or 1 in (25.4mm) copper tailpiece, 1/2 in NPT male
drain
Valve Module, Tank Adaptor, Optional Bypass Valve …………………………………………… Reinforced
NORYL
Inlet-Outlet Manifold ………………………………………………………………………... Brass or reinforced
NORYL
Rubber Parts ………………………………………………………………………. Compounded for cold water
service
Injector size "A" White …………………… Nozzle 0.042 in (1.1 mm) diameter, Throat 0.089 in (2.3 mm)
diameter
Injector size "B" Blue …………………….. Nozzle 0.052 in (1.3 mm) diameter, Throat 0.099 in (2.5 mm)
diameter
Injector size "C" Red …………………… Nozzle 0.059 in (1.51 mm) diameter, Throat 0.099 in (2.5 mm)
diameter
Backwash Controllers Available for ………………………………………………………... 6, 7, 8, 9, 10, 12, 13, 14
in
                                                              (15.2, 17.8, 20.3, 22.9, 25.4, 30.5, 33.0, 35.6 cm) diameter mineral
tanks
                                                                                        All sized to flow 4.5 gpm/sq ft (183 l/min/m2) of bed
area

Pressure Graphs

Содержание AST0922-940

Страница 1: ...ION OPERATING INSTRUCTIONS Model AST0922 940 Serial No Telephone 07 3219 2233 Facsimile 07 3219 2266 Email sales ibcwater com au Website www ibcwater com au FILTRATION WATER TREATMENT PRODUCTS for com...

Страница 2: ...oximately 20ppm based on a sample volume of 10mls Other hardness test kits are available for more accurate testing eg Hardness Tablets Directions Take a 50ml sample of water in a screw capped bottle A...

Страница 3: ...age in litres call D For household situations allow 250 litres per person per day CALCULATION N 1000 x C D x H Select nearest lower whole number If necessary consult your dealer or IBC Water Treatment...

Страница 4: ...s AST0922 940 770 1 4 1540 5 3 22 25 12 22 33 0 70 0 50 1 2 CABINET BRINE CHAMBER POLY MOULDED Operating Pressure 140 690 kPa Temperature 5o x 50o C Electrical 240V 50Hz 3 watts maximum WARNING A pres...

Страница 5: ...t outlet pipes and drain line to control valve as per Instruction Booklet page 5 figure 3 Note The softener is supplied with the Autotrol Series 156 Bypass Valve as standard STEP 2 Remove lid from bri...

Страница 6: ...TOP STRAINER SUPPLIED LOOSE IT IS IMPORTANT THAT THIS STRAINER IS ASSEMBLED TO THE VALVE DURING INSTALLATION THE LENGTH OF THE INTERNAL RISER PIPE IS FACTORY ADJUSTED FOR THE TANK SIZE PROVIDED DO NOT...

Страница 7: ...the timer at the left hand side The Transformer is only suitable for indoor mounting When ordering spare parts Advise that the Timer is the low voltage model Salt Dial Indicator Knob Clock Dial Calend...

Страница 8: ...AST0922 940 Page 8 Water Conditioning Control System Installation Operating and Maintenance Manual Series 255 Valve 940 Control...

Страница 9: ...cing Conditioner into Operation 13 Adjustment of Timer 14 Special Features of Timer Adjustment of Brine Control 14 How to Set the Salt Dial Service 15 Removing the Timer Assembly Removing the Valve As...

Страница 10: ...ve cycle operation provides for down flow service up flow backwash down flow brining down flow slow and fast rinse A sixth position is included for timed refill of the brine tank Valve discs are held...

Страница 11: ...rol Bypass Valve optional Air Check Brine Tube Fitting Connection 1 4 Figure 2 Tank Adaptor Tank Tread 2 1 2 8 male NPSM Drain Connection 3 8 or 1 2 NPT or BSPT Outlet Connection 3 4 or 1 NPT or Inlet...

Страница 12: ...ter pressure at the conditioner is not less than 40psi 280kPa You may elevate an additional 2ft 61cm for each additional 10psi 70kPa of water pressure When the drain line is elevated and empties into...

Страница 13: ...ve s into the not in bypass position Open the water supply valve very slowly to approximately the 1 4 open position Caution If the water supply valve is opened too rapidly or too far resin may be lost...

Страница 14: ...ndicator knob counterclockwise to START Figure 8 It will take a few minutes for regen eration to begin The normal regeneration schedule will not be disrupted Manual Regeneration Electricity is used on...

Страница 15: ...imer assembly for servicing 1 Unplug the power cord 2 Remove the rear cover by pushing back on the tab provided on the cover with your thumb Figure 10 Next lift the cover off the valve 3 To remove the...

Страница 16: ...camshaft Slide the camshaft into the timer It may be necessary to rock the timer slightly to key the camshaft into the timer When the camshaft is slid into place lift he back of the camshaft up while...

Страница 17: ...teps to clean the injector screen and injector 1 Unplug the power cord 2 Shut off the water supply or put the bypass valve s into the bypass position and remove the rear cover Figure 10 3 Relieve syst...

Страница 18: ...Pressure 300 psi 2069kPa Working Pressure 20 to 127 psi 138 to 876 kPa 100 psi max in Canada Voltage 24V 50 Hz 24V 60 Hz 100V 50 Hz 100V 60 Hz 230V 50 Hz 115V 60 Hz Current 50 mA Operating Temperature...

Страница 19: ...1 2 in NPT male drain Valve Module Tank Adaptor Optional Bypass Valve Reinforced NORYL Inlet Outlet Manifold Brass or reinforced NORYL Rubber Parts Compounded for cold water service Injector size A W...

Страница 20: ...AST0922 940 Page 20 Control Valving Identification Valve Disc Operation...

Страница 21: ...AST0922 940 Page 21 Flow Diagrams...

Страница 22: ...AST0922 940 Page 22...

Страница 23: ...1000904 Adj Backwash Extra Salt Long Rinse Long Cycle 1000905 3 Cycle Adj Backwash 11 Motor Option 1 1000802 24V 50 Hz 1000803 24V 60 Hz 1000804 110V 50 Hz 1000805 100V 60 Hz 1000806 230V 50 Hz 10008...

Страница 24: ...AST0922 940 Page 24...

Страница 25: ...AST0922 940 Page 25 Valve Body and Tank Adaptor Module...

Страница 26: ...No 14 for 14 in Diameter Tank 7 1030502 Ball Flow Control 1 8 Injector Assy With O rings 1 1032970 A Injector White 1032971 B Injector Blue 1032972 C Injector Red 9 Injector Cap With O rings 1 1000217...

Страница 27: ...tic Pipe Adaptor Kit 1 1001605 1 in BSPT Plastic Pipe Adaptor Kit 1 1001611 3 4 in BSPT Brass Pipe Adaptor Kit 1 1001610 1 in NPT Brass Pipe Adaptor Kit 1 1001612 1 in BSPT Brass Pipe Adaptor Kit 1 Co...

Страница 28: ...Restricted drain line c Injector plugged d Defective injector e Valve disc 2 and or 3 not closed f Air check prematurely closed a Water pressure must be 20 psi minimum b Remove restriction c Clean in...

Страница 29: ...AST0922 940 Page 29...

Страница 30: ...n be used directly without dissolving before application The recommended dosage for Calcium Hypochlorite is two grains approx 0 1 ounce per cubic foot Complete the following steps to disinfect the con...

Отзывы: