background image

     

 

8

 

Country                             

(for example) 

Standard 

BAC 

Code   

setting

 

Unit 

Germany 

0.5‰ 

0.50 

‰BAC 

Belgium 

0.5‰ 

0.50 

‰BAC 

Denmark 

0.5‰ 

0.50 

‰BAC 

Finland 

0.5‰ 0.2‰ 

0.20 

‰BAC 

France 

0.5‰ 

0.50 

‰BAC 

France (option) 

0.25mg/L 

0.250 

mg/l 

Japan 

0.15mg/L 

0.150 

mg/l 

ltaly 

0.5‰ 

0.50 

‰BAC 

Norway 

0.2‰ 

0.20 

‰BAC 

Netherlands 

0.5‰ 

0.50 

‰BAC 

Spain 

0.5‰ 

0.50 

‰BAC 

Sweden 

0.2‰ 

0.20 

‰BAC 

United Kingdom  0.05% or 0.08% 

0.080 

% BAC 

United States 

0.05% or 0.08% 

0.080 

% BAC 

 
Caution:   

The Systems Settings 
& Calibration has 
passwords control, only 
our authorized service 
centre can process the 
calibration. 

Only AAT authorized 

technician is allowed to 

modify the calibration 

data. 

 

 

     

 

9

   

 

 
 
 

·

When unused for a long time or at a low temperature, the machine will 
take longer warm up time.

 

·

Automatic turn off if left unused within 3 minutes.

 

·

Avoid extreme heat or long term sun exposure.

 

·

If  the  difference  between two successive  readings is 

>

0.01%(0.1

)

,

 

user should test again. 

·

During the breath sampling, do 

NOT

 block the outlet.

 

·

An “Err” show on the display for 3 minutes when user fails to take 

sample. User can press the ON/OFF key to start another test or 
press 

Esc

 to return to “ALCO” mode. 

 

 
 

 

·

Fuel cell Sensor

 

 

·

Range: 

0.00~4.00

BAC

 or 

0.00~0.400%BAC

   

or 0

.00 ~2.00mg/L

 (

  and mg/L convection factor is 2.0) 

 

·

Power Input: 3.7V (rechargeable battery). 

 

 

·

Display: Digital LED display (3 decimal points). 

 

·

Dimension: 123 x 63 x 20 mm. 

 

 

·

Net Weight: 90g.   

 

·

Operating temperature: 5

~50

, for optimum operation

 

 

·

Agency Approval: CE 

 

 

·

Accessories: 4 mouth pieces. 

Specifications 

Important Notes 

     

 

10

 

 

·

Your blood alcohol content (BAC) may change within minutes 

·

Do not use this device to determine if you can drive or not.

 

·

You cannot use the test results in Court.

 

·

Your safest bet is not to mix drinking with driving at all. 

·

Avoid Binge drinking. 

·

  Store  according  to  specifications.  Avoid long  term sun  exposure 
and humidity. 

 
 

 
Never unscrew the AA2000. 

Warranty not valid

 if any screws had being 

loosened or warranty label had being broken; or if the instrument is used 
in a manner not conforming to its intended use. 
 

 

  

Fuel Cell sensor is using the electrochemical reaction for 

platinum against ethanol molecules, gives the most stable and 

reliable measuring technology.   

 

Many  factors  (e.g.  environment,  smoke  &  other  mouth 

impurities)  may  affect  the  BAC  level,  wash  your  mouth 

always before testing, wait at least 15 minutes after your last 

alcohol drink and use the readings for Reference Only.

 

 

Precautions 

Liability for proper function or damage 

 

Fuel Cell Technology 

     

 

11 

 
 
 

When alcohol enters the blood through the alimentary canal (mouth, 
stomach, and intestines), it is distributed through every part of the 
body, including the lungs. 

As the blood passes through the lungs a quantity of alcohol 

passes through the alveoli (tiny sacs of air in the lungs). This quantity 
of alcohol that passes through the alveoli is proportionate to the 
amount of alcohol present in the blood.   

By using a breath testing device it is possible to measure the 

quantity of alcohol that passes through the alveoli, and consequently 
calculate the person’s BAC (Blood Alcohol Concentration). The ratio 
of breath alcohol to BAC is 2000:1 - in simple terms, every 2000 
milliliters of breath will contain the same amount of alcohol as 1 
milliliters of blood. (and some other countries is using 2300:1 or 
2200:1 or 2100:1

 

For this reason it is necessary for a test subject to blow into the 

AAT for at least 6 seconds so that a sufficient deep air lung sample is 
obtained. Failure to do so may result in an artificially low reading. 
Please read the full instructions carefully for proper use of the AAT 
unit. Never drink and drive – the only safe level is zero! 
   

 

Repair/maintenance of the AA2000 should only be carried out 

by trained technician from our authorized Service Center. 

Only authentic 

AA

  spare parts can be used for maintenance. 

Specification subjects to change without notice. 

Made in China 

Maintenance   

How does alcohol testing work? 

Отзывы: