8
Country
(for example)
Standard
BAC
Code
setting
Unit
Germany
0.5‰
0.50
‰BAC
Belgium
0.5‰
0.50
‰BAC
Denmark
0.5‰
0.50
‰BAC
Finland
0.5‰ 0.2‰
0.20
‰BAC
France
0.5‰
0.50
‰BAC
France (option)
0.25mg/L
0.250
mg/l
Japan
0.15mg/L
0.150
mg/l
ltaly
0.5‰
0.50
‰BAC
Norway
0.2‰
0.20
‰BAC
Netherlands
0.5‰
0.50
‰BAC
Spain
0.5‰
0.50
‰BAC
Sweden
0.2‰
0.20
‰BAC
United Kingdom 0.05% or 0.08%
0.080
% BAC
United States
0.05% or 0.08%
0.080
% BAC
Caution:
The Systems Settings
& Calibration has
passwords control, only
our authorized service
centre can process the
calibration.
Only AAT authorized
technician is allowed to
modify the calibration
data.
9
·
When unused for a long time or at a low temperature, the machine will
take longer warm up time.
·
Automatic turn off if left unused within 3 minutes.
·
Avoid extreme heat or long term sun exposure.
·
If the difference between two successive readings is
>
0.01%(0.1
‰
)
,
user should test again.
·
During the breath sampling, do
NOT
block the outlet.
·
An “Err” show on the display for 3 minutes when user fails to take
sample. User can press the ON/OFF key to start another test or
press
Esc
to return to “ALCO” mode.
·
Fuel cell Sensor
·
Range:
0.00~4.00
‰
BAC
or
0.00~0.400%BAC
or 0
.00 ~2.00mg/L
(
‰
and mg/L convection factor is 2.0)
·
Power Input: 3.7V (rechargeable battery).
·
Display: Digital LED display (3 decimal points).
·
Dimension: 123 x 63 x 20 mm.
·
Net Weight: 90g.
·
Operating temperature: 5
℃
~50
℃
, for optimum operation
·
Agency Approval: CE
·
Accessories: 4 mouth pieces.
Specifications
Important Notes
10
·
Your blood alcohol content (BAC) may change within minutes
·
Do not use this device to determine if you can drive or not.
·
You cannot use the test results in Court.
·
Your safest bet is not to mix drinking with driving at all.
·
Avoid Binge drinking.
·
Store according to specifications. Avoid long term sun exposure
and humidity.
Never unscrew the AA2000.
Warranty not valid
if any screws had being
loosened or warranty label had being broken; or if the instrument is used
in a manner not conforming to its intended use.
Fuel Cell sensor is using the electrochemical reaction for
platinum against ethanol molecules, gives the most stable and
reliable measuring technology.
Many factors (e.g. environment, smoke & other mouth
impurities) may affect the BAC level, wash your mouth
always before testing, wait at least 15 minutes after your last
alcohol drink and use the readings for Reference Only.
Precautions
Liability for proper function or damage
Fuel Cell Technology
11
When alcohol enters the blood through the alimentary canal (mouth,
stomach, and intestines), it is distributed through every part of the
body, including the lungs.
As the blood passes through the lungs a quantity of alcohol
passes through the alveoli (tiny sacs of air in the lungs). This quantity
of alcohol that passes through the alveoli is proportionate to the
amount of alcohol present in the blood.
By using a breath testing device it is possible to measure the
quantity of alcohol that passes through the alveoli, and consequently
calculate the person’s BAC (Blood Alcohol Concentration). The ratio
of breath alcohol to BAC is 2000:1 - in simple terms, every 2000
milliliters of breath will contain the same amount of alcohol as 1
milliliters of blood. (and some other countries is using 2300:1 or
2200:1 or 2100:1
)
For this reason it is necessary for a test subject to blow into the
AAT for at least 6 seconds so that a sufficient deep air lung sample is
obtained. Failure to do so may result in an artificially low reading.
Please read the full instructions carefully for proper use of the AAT
unit. Never drink and drive – the only safe level is zero!
Repair/maintenance of the AA2000 should only be carried out
by trained technician from our authorized Service Center.
Only authentic
“
AA
”
spare parts can be used for maintenance.
Specification subjects to change without notice.
Made in China
Maintenance
How does alcohol testing work?