Press the ON/OFF button for 1 second to turn on the machine. 

 

If  no  key  being  press  for  30  seconds,  the  device  will  switch  off 

automatically. 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 

 

1.  Press  the  ON/OFF  button  for  1  second  to  start  the                 

machine and then enter into the “ALCO” interface. 

2.    In the “ALCO” mode, press the ON/OFF once to activate residue 

check.  “

PH

”  flashes  for  a  few  seconds.  It  will  take  longer  if 

residue being detected. 

3.    “

test

”  flashes  for  about  30  seconds  with  beep  tones  when  the 

device ready to test. Carry out the alcohol test during this period.   

 

Also you can press Esc to abort the test. 

i.  Active  test:  Blow  continuously  through  the  mouthpiece  for 

about  6  seconds.  An  audio  signal  is  heard  when  the  breath 

sampling  is  finished.  Stop  blowing  when  you  hear  the  audio 

signal.  “

 

”  flashes  while  the  analysis  is  carried  out.  The 

reading is shown within 6 seconds. 

ii. 

Passive  test:  if  cannot  blow  successfully

,  press  &  hold  ON/OFF 

key and blow 

continuously through the mouthpiece for about 6 

seconds.   

On/Off 

Alcohol Test 

     

 

5

    4. - 0.00

  is shown if the measured blood alcohol content is less 

than  0.1

‰ (

0.05mg

 

alcohol  per litre  of  exhaled  air  or  blood 

alcohol content of 0.01% ). 

      -    the value will be shown digitally in the display if the measured 

blood alcohol content is between 0.1

‰ (

0.05mg

 

alcohol per 

litre  of  exhaled  air  or  blood  alcohol  content  of  0.01%  ).and 

4.00

‰(

2.00  mg

 

alcohol  per  litre  of  exhaled  air  or  blood 

alcohol content of 0.40% ). 

      -    HI  is  shown  in  the  display  if  the  measured  blood  alcohol 

content  is  higher  than  4.00

‰ (

2.00  mg

 

alcohol  per  litre  of 

exhaled air or blood alcohol content of 0.40% ). 

 

 

 

 

 

 

 

                                                       

                                                                                           

 

 

                                                                                             

 

 

 

 

 

 

                                                                                   

 

 
5.    User can  press the  ON/OFF key for another test. “

test

” shows  on 

the display, a beep sounds to begin test again. 

 

6.    The test reading showing on the LED for 90 seconds. 

 

Caution: 

if  the  test  result  exceeds  the  preset  alert  level,  then  “ 

”   

flashes for 15 seconds together with beep alert. 

     

 

6

   

 

 

 

Under the “

ALCO

” mode, press 

Esc

 key for about 3 seconds to enter 

into  the  memory  recall  mode.  Press 

Esc

  key  again  to  scroll  the 

records. 

(Max.10 records). Press and hold 

Esc

 key for 3 seconds to exit 

memory recall mode. Press   

 

In the record mode, the test number and its reading will flash on the 

LED alternatively. For example, the 9

th

 record is 0.50

BAC, then 

r-

09

 

and 

0.50

 will flash alternatively. 

 

 

 

 

 

 

 
             
 

 

 

If memories full, the new reading will overwrite the previous one and (FIFO). 
All the records will be erased if user takes off the rechargeable battery. 

 

   

 

 

 

The  default  unit  and  alert  level  for  this  machine  is  0.5

BAC 

(0.08%BAC  for  US/UK) 

and  no  need  to  set  up  the  following  if  the 

alcohol standard of your country is 0.5

BAC (0.08%BAC for US/UK)

.

 

If  you  want  to  modify  the  unit  and  alert  level,  user 

must 

study  the 

following carefully.   
 

 

 

Turn on the machine and press Esc and go to 

  “

ALCO

, then press 

the ON/OFF and Esc keys together for 3 seconds and than show   

Systems Settings & Calibration 

Test Record

 

     

 

7

"

0000

" (The lower 2-digit 

00

 will flash). Press the 

Esc key to increase the lower 2-digit until 

18

press the ON/OFF button and shift to the upper 2-digit (The upper 
2-digit 

00

 will flash). Press the Esc key to increase the upper 2-digit 

until 

18,   

i.e. 

"

1818

" . Wait for 5 seconds. The machine will enter 

into the unit conversion mode:- 

 

 

Alco Unit Setup 

There are three units can be chosen, that is, 

Permillage

 (‰

B

AC); Percent (%

B

AC); mg/L   

 

Then press ON/OFF key to change the unit (the corresponding 
indicator   

 

%BAC    ‰BAC 

  mg/l

 

    will turn on) 

 

For example: 

 

0.020   

 

 

0.20  

  0.100

 

%BAC              ‰BAC           mg/l 

 

After select the desired unit, press Esc key can go to the alert level 
setting mode. There are 5 alert level can be set, B1, B2, B3, B5 & 
B8.    Please find the attached 

Table 1 for Alert level Vs different 

unit. After selected the unit and alarm value. Wait for 3 seconds, the 
instrument will automatically exit and complete the commissioning 

 

 

   

B1,      B2,    

 

B3,      B5,      B8

 

 

.

       

 

Table 1:    

0.010    0.020    0.030    0.050 

 

0.080   

  % BAC     

  ‰          B

A

C        mg/       

   

 

       

 

 

0.10        0.20      0.30      0.50    0.80   

%BAC   

 

          ‰BAC 

           

 

   

m l     

0.050    0.100    0.150    0.250    0.400   

%BAC 

 

   

‰BAC 

                       

 

mg/l   

  

  

  