(10) DEADMAN SWITCH (Servo Enable Switch)
* Option Setting
The switch mounted on both sides of the Teaching Pendant is connected serially with the Emergency
Stop Switch, and causes e-stop when not pressed (normally, this switch is a "open: a-contact").
Caution: If multiple controllers are connected using link cables, the Deadman SW is enabled only for the axis
of the controller which is connected to the Teaching Pendant.
For the RCP2-CG (cutout relay external type) and ERC/ERC2 series, the Deadman SW is enabled
only when the emergency stop circuit is externally installed. Always read the operating manual of
the controller carefully.