background image

 

21 

 

 
 
(8) Single-guide 

type 

Use the tapped holes in the bracket for installing an actuator of the single-guide type. 

z

  Applicable models: Double-guide type RGD3, RGD4 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Type Tapped 

hole 

diameter 

Tapped 

depth 

Tightening 

torque 

RA3 type 

M5 

8 mm 

3.4 N-m 

RA4 type 

M5 

8 mm 

3.4 N-m 

Tapped mounting hole 

Bracket A 

Bracket B 

Содержание RA3R

Страница 1: ...t Type Built in Type RA3D RGS3D RGD3D RA4D RGS4D and RGD4D Motor Reversing Type RA3R RGS3R RGD3R RA4R RGS4R and RGD4R Rod Type RCA Actuators Motor Straight Type Coupling Type RA3C and RA4C Motor Straight Type Built in Type RA3D and RA4D Motor Reversing Type RA3R and RA4R RCAW Actuators Dustproof Splash proof Type Operating Manual ...

Страница 2: ...ugh failure to do so will not result in injury It should be noted that the instructions under the Caution and Note headings may also lead to serious consequences if unheeded depending on the situation All instructions contained herein provide vital information for ensuring safety Please read the contents carefully and handle the product with due caution Please keep this operating manual in a conve...

Страница 3: ...check the operation area of the equipment to ensure safety Supplying power to the product carelessly may cause electric shock or injury due to contact with the moving parts z Wire the product correctly by referring to the operation manual Securely connect the cables and connectors so that they will not be disconnected or come loose Failure to do so may cause the product to malfunction or cause fir...

Страница 4: ...res if the product is used in any of the following places If proper measures are not taken the product may malfunction 1 Place where large current or strong magnetic field generates 2 Place where arc discharge occurs due to welding work etc 3 Place where noise generates due to electrostatic etc 4 Place where the product may come in contact with radiation z Do not install the product in a place sub...

Страница 5: ...l circuit that will cause the work to drop in case of power failure Configure a control circuit that will prevent the table or work from dropping when the power to the machine is cut off or an emergency stop is actuated z The following conditions must be met in order to improve the straightness of the table movement and ensure the smooth movement of the ball screw and linear guides 1 Flatness of t...

Страница 6: ...d the information carefully to connect the cables properly 1 Do not let the cable flex at a single point 2 Do not let the cable bend kink or twist 3 Do not pull the cable with a strong force 4 Do not let the cable receive a turning force at a single point 6 Do not pinch drop a heavy object onto or cut the cable 5 When fixing the cable provide a moderate slack and do not tension it too tight Steel ...

Страница 7: ...he cable will not become too taut when bent z Do not cause the cables to occupy more than 60 of the space in the cable bearer z Do not lay signal lines together with circuit lines that create a strong electric field z The supplied cables are not robot cables Accordingly never store the cables in a cable bearer z Always use a robot cable for each relay cable Bending radius r z Use a cable bearer wi...

Страница 8: ...5 2 Handling the Actuator Assembly 10 5 2 1 Condition of Shipment from IAI Assembled 10 5 2 2 Handling after Assembly with Peripheral Equipment 10 6 Operating and Storage Environment 11 6 1 Operating Environment 11 6 2 Storage Environment 11 7 Installation 12 7 1 Installing the Main Body 12 8 Wiring Cable 22 9 Connecting the Air Tube of the RCAW Dustproof Splash proof Type 23 10 Maximum Speed 24 1...

Страница 9: ...sing Type RA3R RA4R Types 32 14 6 Replacing the Motor 37 14 6 1 Replacing the Motor of the Motor Straight Type Coupling Type RA3C RA4C Types 37 14 6 2 Replacing the Motor of the Motor Reversing Type RA3R RA4R Types 44 14 7 Replacing the Bellows of the RCAW Dustproof Splash proof Type 50 15 Cable Drawings 53 ...

Страница 10: ......

Страница 11: ... the unit when it is in operation or when the power is ON since this is dangerous 2 2 Maintenance and Inspection When doing maintenance and inspection work always shut down the controller power first When doing inspection make sure that no one can inadvertently turn the power ON Make sure that a sign indicating work in progress is clearly visible If several persons are working be sure to watch out...

Страница 12: ...t wear out with use stainless sheet etc Unit seems to be noisy or similar impressions that do not affect machinery performance Damage resulting from improper handling by the user or lack of proper maintenance Any alterations made by other than IAI or its representatives Breakdowns caused by using controllers made by other manufacturers Any damages caused by fire and other natural disasters or acci...

Страница 13: ...aight Type Coupling Type No Guide z RCA RA3C RCA RA4C Caution The cable directly connected to the actuator is not robot cable even when ordered with robot cable option When designing please be sure not to give repeated bending loads to this cable The robot cable is applicable only to the connecting cables Rod side Motor side Right Left Rod Rod cover Cylinder tube Head cover Motor unit Cable Rod ti...

Страница 14: ...o the actuator is not robot cable even when ordered with robot cable option When designing please be sure not to give repeated bending loads to this cable The robot cable is applicable only to the connecting cables Rod side Motor side Right Left Rod Rod cover Cylinder tube Head cover Motor unit Cable Rod tip adapter ...

Страница 15: ... not robot cable even when ordered with robot cable option When designing please be sure not to give repeated bending loads to this cable The robot cable is applicable only to the connecting cables Rod side Motor side Right Left Rod Rod cover Cylinder tube Head cover Motor unit Cable Rod tip adapter Pulley case ...

Страница 16: ... actuator is not robot cable even when ordered with robot cable option When designing please be sure not to give repeated bending loads to this cable The robot cable is applicable only to the connecting cables Rod side Motor side Right Left Rod Rod cover Cylinder tube Head cover Motor unit Cable Guide bracket Guide bearing Guide rod ...

Страница 17: ... actuator is not robot cable even when ordered with robot cable option When designing please be sure not to give repeated bending loads to this cable The robot cable is applicable only to the connecting cables Rod side Motor side Rod Rod cover Cylinder tube Head cover Motor unit Cable Guide bracket Guide bearing Guide rod Right Left ...

Страница 18: ...ctuator is not robot cable even when ordered with robot cable option When designing please be sure not to give repeated bending loads to this cable The robot cable is applicable only to the connecting cables Rod side Motor side Right Left Rod Rod cover Cylinder tube Head cover Motor unit Cable Bellows Intake exhaust port Rod tip adapter ...

Страница 19: ...osition Do not climb on top of the shipping box Do not place heavy objects on top of the shipping box 5 1 2 Handling the Actuator After It is Unpacked Lift the actuator up by the base to remove it from the packing When transporting the actuator be careful not to hit it against nearby structures or object In particular exercise caution to protect the motor unit and pulley case against impact Do not...

Страница 20: ... as not to apply impact to the assembly or cause it to bounce After unpacking handle the actuator assembly correctly by observing the instructions given below 5 2 2 Handling after Assembly with Peripheral Equipment When transporting the actuators that have been assembled with peripheral equipment either at IAI or on your site observe the instructions given below Secure the rod so that it will not ...

Страница 21: ...hich an operator can work without protective gear RCA Work space needed for maintenance inspection Motor straight type Motor reversing type If you are using the dustproof splash proof type RCAW type consult IAI beforehand This product is not designed by considering chemical resistance Contact IAI for splash proof resistance to liquids other than water 6 2 Storage Environment The storage environmen...

Страница 22: ...tuator using screws set on the rod or head side of the actuator z Applicable models All models Type MA MB RA3 type M26 x 1 5 M35 x 1 5 RA4 type M30 x 1 5 M40 x 1 5 Straight type Rod cover Cylinder tube Head cover Motor unit Reversing type MA MB Pulley case Rod Rod cover MA Cylinder tube Head cover MA ...

Страница 23: ...alling the actuator Use this flange if necessary z Applicable models All models Mating material is steel Mating material is aluminum Screw size M6 M6 Tightening torque 12 3 N m 5 4 N m Straight type Mounting hole Affixing nut Flange Straight type Mounting hole Affixing nut Flange ...

Страница 24: ... Mating material is steel Mating material is aluminum Screw size M6 M6 Tightening torque 12 3 N m 5 4 N m Reversing type Mounting hole Affixing nut Flange Mounting hole Affixing nut Flange Reversing type ...

Страница 25: ...M6 M6 Tightening torque 12 3 N m 5 4 N m Caution Affix the actuator using two feet optional one in the front and the other in the back If affixed using only one foot in the front or back the actuator may be negatively affected due to insufficient rigidity Straight type Mounting hole Affixing nut Foot A Affixing nut Affixing nut Mounting hole Foot B Reversing type Mounting hole Mounting hole Affixi...

Страница 26: ...runnion if necessary z Applicable models RA3C RA3D RA4C RA4D Mating material is steel Mating material is aluminum Screw size M6 M6 Tightening torque 12 3 N m 5 4 N m Straight type Mounting hole Affixing nut Trunnion ring Straight type Mounting hole Affixing nut Bracket B Bracket A Trunnion ring Bracket A Bracket B ...

Страница 27: ...nstalled horizontally using any of the aforementioned means add a guide or other appropriate mechanism to prevent the rod from receiving the actuator weight Caution The optional clevis and trunnion are designed so that the fulcrum shaft can only receive radial load In a condition where play is not permitted or thrust load is received the customer must design a separate bearing structure Caution Th...

Страница 28: ...ult the bush may wear quickly or internal mechanical parts may be damaged If the actuator is installed horizontally using any of the aforementioned means add a guide or other appropriate mechanism to prevent the rod from receiving the actuator weight Caution The optional clevis and trunnion are designed so that the fulcrum shaft can only receive radial load In a condition where play is not permitt...

Страница 29: ...t is available for installing the actuator Use this rear mounting bracket if necessary z Applicable models Motor reversing type RCA RA3R RCA RA4R Type Tapped hole diameter Tapped depth Tightening torque RA3 type M4 6 mm 1 8 N m RA4 type M4 7 mm 1 8 N m Reversing type Tapped mounting hole ...

Страница 30: ...racket for installing an actuator of the double guide type z Applicable models Double guide type RGD3 RGD4 Type Tapped hole diameter Tapped depth Tightening torque RA3 type M5 8 mm 3 4 N m RA4 type M5 8 mm 3 4 N m Tapped mounting hole Bracket A Bracket B ...

Страница 31: ...racket for installing an actuator of the single guide type z Applicable models Double guide type RGD3 RGD4 Type Tapped hole diameter Tapped depth Tightening torque RA3 type M5 8 mm 3 4 N m RA4 type M5 8 mm 3 4 N m Tapped mounting hole Bracket A Bracket B ...

Страница 32: ...it the load on the cable Never cut and or reconnect the cables supplied with the product for the purpose of extending or shortening the cable length The cables supplied with the actuator offer excellent flexibility but they are not robot cables If the cables are to be stored in a movable cable duct cable bearer etc use robot cables For cable modification please contact your IAI sales representativ...

Страница 33: ... 5 mm on the intake exhaust port and guide the air tube to a location where the external environment assures the tube will not come in contact with water Applicable tube Shown below is a representative model of air tube that can be installed on the RCAW TU1065 Polyurethane tube Manufacturer SMC Caution The air tube should not be more than 3 m long ...

Страница 34: ... If the maximum speed limit is exceeded noise may increase or vibration may occur due to resonance of the ball screw shaft in which case the service life of the actuator may be significantly reduced If multiple actuators are used together with each actuator operating independently create programs where each actuator does not exceed the applicable maximum speed see the table above If operations of ...

Страница 35: ... the actuator in the moving direction of the load Do not allow the rod slide shaft to receive rotational torque Doing so may damage the internal parts Tighten the nut at the tip of the rod while securely holding the rod using a wrench of size 17 RA4 or 13 RA3 12 Actuators with a Switch Optional On actuators with a switch the switch is stored inside the actuator body on the motor side Do not increa...

Страница 36: ...he actuator has a rated acceleration deceleration of 0 3 G and is combined with a controller of power saving specification with lower peak current Blank Conventional specification The actuator has a rated acceleration deceleration of 0 3 G and is combined with a conventional controller Example RCA RA3C I 20 10 50 A1 S HA High acceleration deceleration type RCA RA4C I 20 10 50 A1 S LA Power saving ...

Страница 37: ... 2 Power saving specification ACON C 20ILA NP 2 0 3 Conventional specification ACON C 20I NP 2 0 Standard specification high acceleration deceleration option Power saving option Actuator Rated Maximum 2 Rated Maximum 2 RA3C RGS3C RGD3C 1 7 A 5 1 A 1 7 A 3 4 A RA4C RGS4C Load current 1 RGD4C 1 3 A 4 0 A 1 3 A 2 2 A 1 When the power is turned on rush current corresponding to around 5 to 12 times the...

Страница 38: ...reafter 1 Apply grease to the sliding surface of the rod at the startup check if grease has been consumed or every three months For the RCAW dustproof splash proof type apply grease when the bellows is changed 14 2 Visual Inspection of the Machine Exterior Check the following items visually Body Loose mounting bolts Cables Damage to cables or connection to connector box General Unusual noise or vi...

Страница 39: ...plicable grease Kyodo Yushi Multemp LRL3 Warning Never use any fluorine based grease It will cause a chemical reaction when mixed with a lithium based grease and may cause damage to the actuator 2 How to apply grease Apply grease over the entire surface of the rod ...

Страница 40: ... to withstand several millions of flexing loads As a practical guideline replace the reduction belt when any of the conditions listed below is observed The teeth and end faces of the belt have worn significantly The belt has swollen due to deposits of oil etc Cracks and other damages are found on the teeth or back of the belt The belt has broken 14 5 2 Applicable Belt RA3R 60S2M124R Rubber cleanro...

Страница 41: ...or unit and pull the string to the specified tension using a tension gauge In this condition uniformly tighten the motor unit affixing bolts Recommended tightening torque of adjustment bolts 162 N cm 16 5 kgf cm Tension 2 5 kgf Motor unit affixing bolts Use an Allen wrench of 2 5 mm across flats Motor unit affixing bolts Use an Allen wrench of 2 5 mm across flats ...

Страница 42: ... mechanical end In this position loosen the motor unit affixing bolts and replace the belt 2 Restore the home position Affix the rod at a position 2 mm from the mechanical end on the home side pass the belt and adjust the belt to the specified tension 3 Perform homing using a PC or teaching pendant and check for deviation from the initial home position If there is a deviation adjust the home offse...

Страница 43: ...osition Warning If the actuator is installed vertically move it after turning on the controller power and forcibly releasing the brake At this time beware of danger as the actuator may drop suddenly Always provide a support to brace the actuator hand to prevent sudden drop so as not to pinch fingers or damage the load M3 hexagon socket head screws M4 hexagon socket head screws Cause the rod to pro...

Страница 44: ...ust it to achieve proper alignment The ball screw side should be at a position where the rod projects 2 mm from the mechanical end After the check attach a new belt while holding the pulleys on both sides in position Motor unit affixing bolts Use an Allen wrench of 2 5 mm across flats Motor unit affixing bolts Use an Allen wrench of 2 5 mm across flats Motor side Ball screw side Initial countermar...

Страница 45: ...n gauge to the specified tension In this condition uniformly tighten the motor unit affixing bolts Recommended tightening torque for adjustment bolts 162 N cm 16 5 kgf cm Tension 2 5 kgf Motor unit affixing bolts Use an Allen wrench of 2 5 mm across flats Motor unit affixing bolts Use an Allen wrench of 2 5 mm across flats ...

Страница 46: ...ute reset must be performed Check for deviation from the initial home position If there is a deviation adjust parameter No 22 Home offset if you are using an ACON controller If you are using an ASEL controller adjust axis specific parameter No 12 Home preset If your controller is of absolute encoder specification perform homing after changing the parameter and then perform an absolute reset M3 hex...

Страница 47: ...n 2 mm from the mechanical end In this position replace the motor 2 Perform homing using a PC or teaching pendant and check for deviation from the initial home position If there is a deviation adjust the home offset if you are using an ACON controller If you are using an ASEL controller adjust the home preset Replacement motor unit Coupling with screws Home position Z phase ON position Mechanical ...

Страница 48: ...g the brake At this time beware of danger as the actuator may drop suddenly Always provide a support to brace the actuator hand to prevent sudden drop so as not to pinch fingers or damage the load 2 Using an Allen wench of 2 mm across flats remove the two motor unit affixing bolts on the right and left Cause the rod to project 2 mm from the mechanical end Apply countermarks once the rod has projec...

Страница 49: ...a countermark on the cylinder tube at a position corresponding to the tab on the motor unit so that the motor unit and cylinder can be aligned in the correct position later on 4 Apply grease on the actuator coupling Tab on the motor unit Apply a countermark at a position corresponding to the tab on the motor unit ...

Страница 50: ...hat of the actuator coupling adjusted to a position corresponding to a rod projection of 2 mm from the mechanical end Apply countermarks to identify the current motor position phase Z position and coupling Align the tab on the replacement motor unit with the countermark on the cylinder Position the couplings Coupling Replacement motor unit After the coupling has been inserted apply countermarks on...

Страница 51: ...rench of 2 mm across flats Similarly turn the coupling and motor shaft simultaneously until the other screw is seen through the hole and tighten the setscrew Coupling setscrew hole Turn the coupling and motor shaft simultaneously until a setscrew on the coupling is seen through the hole Thereafter tighten the hexagon socket head setscrew using an Allen wrench of 2 mm across flats ...

Страница 52: ...confirm that the orientation of the actuator coupling adjusted to a position corresponding to a rod projection of 2 mm from the mechanical end corresponds to the position of the coupling in the replacement motor unit Apply countermarks on the replacement motor unit and coupling Coupling Replacement motor unit Align the tab on the replacement motor unit with the countermark on the cylinder Confirm ...

Страница 53: ... is of absolute encoder specification an absolute reset must be performed Check for deviation from the initial home position If there is a deviation adjust parameter No 22 Home offset if you are using an ACON controller If you are using an ASEL controller adjust axis specific parameter No 12 Home preset If your controller is of absolute encoder specification perform homing after changing the param...

Страница 54: ...he rod at a position 2 mm from the mechanical end on the home side pass the belt and adjust the belt to the specified tension 3 Perform homing using a PC or teaching pendant and check for deviation from the initial home position If there is a deviation adjust the home offset if you are using an ACON controller If you are using an ASEL controller adjust the home preset Replacement motor unit Z phas...

Страница 55: ...bolts using an Allen wrench of 2 5 mm across flats Slide the motor and loosen and remove the belt After the belt has been removed remove the motor unit affixing bolts Motor unit affixing bolts Use an Allen wrench of 2 5 mm across flats Motor unit affixing bolts Use an Allen wrench of 2 5 mm across flats M3 hexagon socket head screws M4 hexagon socket head screws ...

Страница 56: ...46 Replacement motor 3 Take out the motor 4 Install the replacement motor Loosely tighten the motor unit affixing bolts ...

Страница 57: ...or may drop suddenly Always provide a support to brace the actuator hand to prevent sudden drop so as not to pinch fingers or damage the load 6 Check the following points before restoring the home position The motor side should be aligned with the initial countermark If the position is offset adjust it to achieve proper alignment The ball screw side should be at a position where the rod projects 2...

Страница 58: ...llen wrench of 2 5 mm across flats 7 Adjust the belt tension Pass a looped strong string or long tie band around the motor cover and pull it with a tension gauge to the specified tension In this condition uniformly tighten the motor unit affixing bolts Recommended tightening torque for adjustment bolts 162 N cm 16 5 kgf cm ...

Страница 59: ...ute reset must be performed Check for deviation from the initial home position If there is a deviation adjust parameter No 22 Home offset if you are using an ACON controller If you are using an ASEL controller adjust axis specific parameter No 12 Home preset If your controller is of absolute encoder specification perform homing after changing the parameter and then perform an absolute reset M3 hex...

Страница 60: ... bellows unit RA3 JB RA3 stroke RA4 JB RA4 stroke Phillips screwdriver Torque driver Grease Kyodo Yushi Multemp LRL3 Procedure 1 Loosen the front and rear metal fittings affixing the bellows and remove the bellows Loosening of front metal fitting Loosening of rear metal fitting Removal of bellows Bellows has been removed ...

Страница 61: ...51 Bellows Install a metal fitting on the bellows 2 Apply grease evenly over the entire cylinder surface Apply grease evenly over the entire surface 3 Install a metal fitting on the bellows ...

Страница 62: ...he replacement new bellows and tighten the screws of the front and rear metal fittings affixing the bellows Tighten the screws to the specified torque using a torque driver Installation of bellows Tightening of rear metal fitting Tightening of front metal fitting ...

Страница 63: ...Controller end Actuator end 15 Cable Drawings 1 Motor cable Model CB ACS MA Wire Color Signal No No Signal Color Wire Red U 1 1 U Red White V 2 2 V White AWG22 crimped Black W 3 3 W Black AWG22 crimped 1 3 ...

Страница 64: ...nge Green Green Purple Purple Gray Red Black Ground Black Gray Red White blue in the wire color field indicates the band color insulator color Ground LS LS BK BK A A B B SD Z SD Z BAT BAT VCC GND FG No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 No A A B B LS LS FG FG Z Z PS BAT BAT SD SD VCC GND VCC GND LS BK BK LS BK BK 2 Encoder cable robot encoder ...

Страница 65: ...MEMO 55 ...

Страница 66: ...MEMO 56 ...

Страница 67: ......

Страница 68: ...912 Atlanta Office 1220 E Kenneston Circle Marietta GA 30066 TEL 678 354 9470 FAX 678 354 9471 Website www intelligentactuator com Ober der Röth 4 D 65824 Schwalbach am Taunus Germany TEL 06196 88950 FAX 06196 889524 The information contained in this document is subject to change without notice for the purpose of product improvement Copyright 2008 Apr IAI Corporation All rights reserved ...