6.
Operating and Storage Environment
6.1 Operating
Environment
The actuator should be set up in an environment, which meets the following criteria:
•
Avoid
direct
sunlight.
•
Avoid radiant heat from strong heat sources such as a furnace.
•
Ambient temperature should be 0 ~ 40
°
C.
•
The humidity should be less than 85% and there should be no condensation.
•
Avoid exposure to corrosive or combustible gases.
•
The area should have very little dust and be suitable for normal assembly operations. (RCA)
•
Avoid exposure to oil mist or fluids used in cutting. (RCA)
•
Ambient air should be free from cutting or grinding fluids containing sulfur.
•
The unit should not be subject to impact or vibration.
•
Avoid extreme electromagnetic waves, ultraviolet rays and radiation.
In general, the environment should be one in which an operator can work without protective gear.
(RCA)
Work space needed for maintenance/inspection
[Motor straight type]
[Motor reversing type]
* If you are using the dustproof/splash-proof type (RCAW type), consult IAI beforehand.
This product is not designed by considering chemical resistance. Contact IAI for splash-proof
resistance to liquids other than water.
6.2 Storage
Environment
The storage environment should be similar to the operating environment. In addition, you must take
precautions against condensation if the unit is to be stored for a long period of time. Unless there are
special instructions, we do not include moisture absorption agents when shipping the unit. If you are
storing the unit where condensation might occur, then you must treat the entire package or treat the unit
itself after it is unpacked to prevent condensation. The unit can withstand up to 60
°
C during a short
storage interval but only up to 50
°
C if the storage period is longer than one month.