LQ-401CL
56
with G
PER
Programmable
Exposure - Red
PER=[Param.]<CR><LF
>
PER?<CR><LF>
Full resolution
Sub-sampling/Windowing
840 to 1194752 clocks
- 1 clock is 11.9 ns
Only valid for TR=1
PEG
Programmable
Exposure
-
Green
PEG=[Param.]<CR><LF
>
PEG?<CR><LF>
Full resolution
Sub-sampling/Windowing
840 to 1194752 clocks
- 1 clock is 11.9 ns
Only valid for TR=1
PEB
Programmable
Exposure
-
Blue
PEB=[Param.]<CR><LF
>
PEB?<CR><LF>
Full resolution
Sub-sampling/Windowing
840 to 1194752 clocks
- 1 clock is 11.9 ns
Only valid for TR=1
PEIR
Programmable
Exposure - NIR
PEIR=[Param.]<CR><LF
>
PEIR?<CR><LF>
Full resolution
Sub-sampling/Windowing
800 to 1194752 clocks
- 1 clock is 11.9 ns
Only valid for TR=1
AH
One-push AWB
shutter
AH=[Param.]<CR><LF>
0=Activate one-push AWB
shutter
Only valid for TR=1
AHRS
Inquire the
status after
one-push AWB
shutter
AHRS?<CR><LF>
<One of following values will
be replied from the camera>
0=AWB has not been finished
yet.
1=Succeeded.
2=Error1 - G image was too
bright.
3=Error2 - G image was too
dark.
4=Error3 - Timeout-error
occurred.
C - Trigger mode
TR Trigger Mode
TR=[Param.]<CR><LF>
TR?<CR><LF>
0=No-shutter mode
1=Shutter-Select mode
2=Pulse Width Control
mode
TG Trigger Origin
TG=[Param.]<CR><LF>
TG?<CR><LF>
0=Internal
1=External
TG=0 is available
when TR=0 or TR=1
TI
Trigger Input
TI=[Param.]<CR><LF>
TI?<CR><LF>
0=Camera-Link
1=12pin
TP Trigger
Polarity
TP=[Param.]<CR><LF>
TP?<CR><LF>
0=Active-Low
1=Active-High
ARST
Auto reset
mode
ARST=[Param.]<CR><LF>
ARST?<CR><LF>
0=OFF
1=Auto Reset
2=Auto Interval
D - Image format
BI
Binning
BI=[Param.]<CR><LF>
BI?<CR><LF>
0=Binning Off, 1=Binning On
BA Bit allocation
BA=[Param.]<CR><LF>
BA?<CR><LF>
0=24bit, 1=30bit
TS Test Pattern
TS=[Param.]<CR><LF>
TS?<CR><LF>
0=Off
1=Color Bar
2=Gray Pattern 1
3=Gray Pattern 2
4=White
Off at power up