LQ-401CL
52
7.32 Command SDS – Request Status After Executing Shading Correction
Command
This command returns the status of the shading correction function, with the following parameters:
0=Not completed yet
1=Succeeded
2=Error1: Image too bright
3=Error2: Image too dark
4=Error3: Timeout occurred
7.33 Command SRO – Sensor Read Out
This command selects the readout format from the sensor.
Settings:
0= OFF (Full Frame)
1= Sub-sampling
2= Windowing
7.34 Command SGR, SGG, SGB, SGIR – Sensor Gain Set R, G, B and NIR
This command sets the reference gain for gain control.
Settings:
0= Low Gain
1= High Gain
Common for all channels
7.35 Command TG – Trigger Origin
Selects whether an external signal or an internal clock generator is used as a trigger
source.
Settings:
0=Internal clock generator
1=External signal
Associated commands:
TI
TP
7.36 Command TI – Trigger Input
Selects whether the External Trigger input signal is taken from the Camera Link connector, or from
the 12-pin connector. The 12-pin connector trigger input can be terminated by a 75 ohm terminator.
This is selected by a rear panel DIP-switch (SW1).
Settings:
0=Camera Link connector
1=12-pin connector
7.37 Command TP – Trigger Polarity
Settings:
0=Active Low (factory default)
1=Active High