LQ-401CL
43
7. Functions listed alphabetically by command acronyms
The following is not a complete list. Please refer to Chapter 8, Serial Communication and Command
List, for the details.
7.1 Command AHRS – Request Status After One-Push AWB
This command returns the status of the one-push AWB function, with the following parameters:
0=AWB not completed yet
1=Succeeded
2=Error1: Green image too bright
3=Error2: Green image too dark
4=Error3: Timeout occurred
7.2 Command AL – Automatic Line Rate Reference Level
This command sets a target luminance level when command AR is activated.
Settings:
0 to 1023 (for 40-bit)
Applicable modes:
No-shutter with internal trigger
Shutter-Select with internal trigger
Associated functions:
Command AR
7.3 Command AR – Automatic Line Rate Setting
The line rate can be adjusted from 1L to 1024L. This function will calculate and set the line rate of
the camera based on the Automatic Line Rate Reference Level (as set in command AL) and the
scene illumination. Please note that the aspect ratio of the scanned object will change as the line
rate is changed.
Settings:
0 (activate automatic process)
Applicable modes:
No-shutter with internal trigger
Shutter-Select with internal trigger
Associated functions:
Command AL
Note
The data can be stored in the camera memory for next start up.
7.4 Command ARST – Auto Reset Mode
This function sets the reset mode to be used
Settings 0: OFF
1: Auto Reset
2: Auto Interval
Factory default is 0 (off).
1. Auto Reset Mode
In No Shutter External mode, when a trigger pulse does not occur after more than 52 ms,
and the first trigger pulse is input after this absence, the video signal which was exposed
during the trigger absence is output. If Auto Reset Mode is set to ON, the video, LVAL and
DVAL during the trigger absence are not output and when the second trigger is input, the
video, LVAL and DVAL are output again.