7.2 Mounting Surface
Caution:
As the diagram above shows, the slider travelling plane is the reference plane for the actuator base and the lower
surface. When travelling precision is required, use this as the reference plane for mounting.
• The mounting table should have sufficient rigidity to avoid generating vibration.
• The surface where the actuator will be mounted should be machined or be equally level and the flatness tolerance between
the actuator and the table should be within 0.05mm.
• Provide enough space around the actuator to permit maintenance work to be done.
• The side and bottom surfaces of the actuator base are used as the reference surfaces for the slider run.
• In the case that the running accuracy is required, mount the slider using these surfaces as the reference.
Please follow the diagrams below for machining to mount on to the frame using the base surface:
8
Standard
side
Machine Type
A dimensions (mm)
Small
2~5
Medium
2~5
A
Under R0.3
Standard
side
Standard
side