4. Wiring
4.2
Configuration Using a Gateway Unit
4.2.1
SIO Communication Connection Using a Relay Terminal Block
(Note 1) If the total length of the communication cable is 10 m or longer and you experience
communication errors, connect a terminal resistor to the last axis.
(Note 2) If the actuators use different power supplies, align 0 [V] on all power supplies.
(Note 3) The gateway unit power must be the same as 0 V of the ERC2 control power.
(Note 4) Connect the shielded wire of each axis to FG.
(Note 5) If the overall length of link cable exceeds 30 m, use wire of 22AWG or larger size.
PC software
RS232C type <RCM-101-MW>
USB type <RCM-101-USB>
Optional
Teaching
pendant
Relay terminal
block
Actuator 1
Actuator 2
Actuator 3
One-pair shielded cable
(Fabricated by the customer)
Terminal resistor
1/2W, 220
:
Actuator 16
Gateway
unit
J.S.T.
Mfg.
J.S.T.
Mfg.
24-VDC control power, motor power,
brake signal, ground, shield
Fabricated by the customer
Power & I/O cable