4. Installation
Environment
Do not use this product in the following environment.
• Location where the surrounding air temperature exceeds the range of 0 to 40
°
C
• Location where condensation occurs due to abrupt temperature changes
• Relative humidity less than 10%RH or greater than 85%RH
• Location exposed to corrosive gases or combustible gases
• Location exposed to signi
fi
cant amount of dust, salt or iron powder
• Location subject to direct vibration or impact
• Location exposed to direct sunlight
• Location where the product may come in contact with water, oil or chemical droplets
When using the product in any of the locations speci
fi
ed below, provide a suf
fi
cient shield.
• Location subject to electrostatic noise
• Location where high electrical or magnetic
fi
eld is present
• Location with the mains or power lines passing nearby
For Dust-proof type (Equivalent to IP53)
The protection structure level is enhanced to IP53 with the installation of the dust-proof cover (option).
“5” in IP53 stands
for the structure
Where the amount of dust which can affect the normal operation and safety,
can not enter the unit.
“3” in IP53 stands
for the structure
Where normal operation and safety is not affected even with the precipitation
from above.