PDS-II Power Distribution System II
Caution: Although the PDS-II system is UL Listed IAC Industries STRONGLY RECOMMENDS
that the PDS-II system be connected to or disconnected from the power source by a qualified
professional electrician ONLY. Incorrect or faulty installation of this system could cause severe
personal injury and property damage.
PDS-II Interconnect Cable Installation:
PLEASE NOTE: For proper installation of interconnect cable on D/S benches the orientation of
the uprights need to be the same as S/S uprights with the Number 1 and 3 Outlet blocks on the
upright facing your right side and the Number 2 and 4 Outlet blocks facing your left side on each
upright. The Number 2 and 4 Outlet blocks on one upright can not face each other for the
interconnect cable to installed properly.
HARDWARE KIT HWR278, HWR 279, HWR 280
ITEM DESCRIPTION
QTY
A
Screw, #10 x .625 PPH SMS Zinc
9
B
Conduit, One Hole Strap Rigid 3/4
3
C
PDS-II Duplex Trim Bezel
4
D
PDS-II Duplex Trim Bezel Blank
1
E
PDS-
II Station Interconnect 48”, 60”, or 72” 1
Step 1:
Fit the interconnect cable end connector into the trim panel of the right side upright by tilting it in
and up into the trim panel cut out, pushing it flat against the distribution block and then pushing it
down into the connectors in the distribution block. Attach the end connector to the distribution
block with the screws supplied in the hardware kit.
Step 2:
Take two of the bezels from the above hardware kit and carefully fit them over the upright
interconnect cable.
Step 3:
Slide the bezel along the interconnect cable, fit it over the cutout in the trim panel of the upright
and gently snap it into place.