NSTALLATION OF FLOOR
MOUNTING TEMPERATURE SENSORS
(Fig. 6)
Installation of floor temperature sensors is performed
when heating mat or section is being installed. In each area
its own temperature sensor is installed. The sensors installa
tion is performed via a junction box. The sensors are placed
in corrugated plastic tube. The end face of the tube is to be
sealed to prevent penetration of tile fixing mixture or cement
mortar in the course of heated floor arrangement. The end of
the corrugated tube with a sensor inside is placed approx.
50 cm away from the wall, at the height of the heating cable
centrally located between loops. If required the plastic tube
can be placed within a channel in the floor to minimize overall
height. It is recommended that the temperature sensor is
placed through the corrugated tube in the event access is
required to the floor sensor. Should the floor sensor cable
require extending this is possible up to a maximum of
25 metres.