6-17
Operation
To enable/disable Automated Mode, access the System Parameters menu
(see Section 5.5.1,) then set the "Automated Mode" option to "On". When
Automated Mode is enabled, CMS-6R4 functions will change as follows:
1.
All Password Security Suppressed:
When a user attempts to access
command mode, the password prompt will not be displayed at either the
COM / RS232 Port or the Network Port. Unless specifically restricted
by the IP Security Function, all users will be allowed to access both
switching and configuration functions, and all commands will be
immediately accepted without the requirement to enter a password.
2.
Status Screen Suppressed:
The status screens will not be automatically
displayed after commands are successfully executed. Note however,
that the /S command can still be invoked to display the status screen as
needed.
3.
"Sure?" Prompt Suppressed:
All commands are executed without
prompting for user confirmation.
4.
Error Messages Suppressed:
If the
[Enter]
key is pressed without
entering a command, the CMS-6R4 will not respond with the "Invalid
Command" message. Note however, that an error message will still be
generated if commands are invoked using invalid formats or arguments.
All other status display and configuration commands will still function as
normal.
Содержание CMS-6R4
Страница 2: ......
Страница 8: ...vi CMS 6R4 Series User s Guide ...
Страница 14: ...2 4 CMS 6R4 Series User s Guide ...
Страница 20: ...3 6 CMS 6R4 Series User s Guide ...
Страница 114: ...10 16 CMS 6R4 Series User s Guide ...
Страница 115: ...Apx 1 A Interface Description A 1 Serial RS232 Port Interface Figure A 1 Serial Port Interface ...
Страница 123: ......