background image

Table of Contents

Information

  Important Information 

  Specifications 

  CareSens N Blood Glucose Monitoring System 

7

  CareSens N Blood Glucose Test Strip 

8

  CareSens N Blood Glucose Meter 

10 

  CareSens N Blood Glucose Meter Display 

11 

Preparation

  Setting up Your System 

12  

    Adjusting the Date, Time and Unit 

12 

    Setting the Sound On/OFF 

15 

    Setting the Test Result Reset 

16 

  Checking the System 

17  

    Control Solution Testing 

18 

    Comparing the Control Solution Test Results 

20 

Testing

  Using the Lancing Device 

21  

    Preparing the Lancing Device for Blood Sample Retrieval 

22 

    Preparing the Meter and Test Strip 

24 

     Flagging Post-meal Test Results 

24  

     Applying Blood Sample 

25 

     Discarding Used Lancets 

27 

  Alternative Site Testing 

28 

  HI and Lo Messages 

31  

  Target Blood Glucose Ranges 

32 

Additional Functions

  Meter Memory 

33 

    Viewing Averages Stored in the Meter’s Memory 

33 

  Setting the Alarm Function 

35

    Setting the Post-meal alarm (PP2 alarm) 

35

    Setting the Time Alarm (alarm 1 ~ 3) 

36

Maintenance

  Replacing the Batteries 

38 

  Caring for Your System 

39 

  Understanding Error and Other Messages 

40 

  General Troubleshooting 

42

  Performance Characteristics 

43

  Warranty Information 

45 

www.i-sens.com  

3

Содержание CareSens N Voice

Страница 1: ...c All Rights Reserved PGA1E3121 REVx 02 2012 The Biosensor Exppert i SENS Inc 465 6 Wolgye4 dong Nowon gu Seoul 139 845 Korea www i sens com Medical Technology Promedt Consulting GmbH Altenhofstrasse...

Страница 2: ...stem The system provides you with safe convenient and painless blood glucose in vitro i e outside the body diagnostic monitoring You can obtain accurate results in just 5 seconds with a small 0 5 bloo...

Страница 3: ...Lancing Device 21 Preparing the Lancing Device for Blood Sample Retrieval 22 Preparing the Meter and Test Strip 24 Flagging Post meal Test Results 24 Applying Blood Sample 25 Discarding Used Lancets 2...

Страница 4: ...reSens N strip The average hematocrit range is between 30 and 50 However people with severe anemia and newborns may have higher hematocrit and this can affect the test results Very high 60 or more or...

Страница 5: ...C 50 104 F Relative humidity 10 90 Hematocrit 20 60 CareSensNBloodGlucoseMonitoringSystem Components 01 CareSens N Blood Glucose Meter 02 Lancing Device 03 Lancets 10 04 Owner s Booklet 05 Quick Refe...

Страница 6: ...ps past the expiration date Test strips in new unopened containers and test strips in containers that have been opened can be used up until the expiration date printed on the test strip box and contai...

Страница 7: ...lts stored in the memory are displayed alarm appears when the time alarm has been set mmol L unit for measuring blood glucose Battery icon indicates meter battery is running low and needs to be replac...

Страница 8: ...adjust until the correct year appears Press and hold button to scroll through the numbers quickly After setting the year press the S button to confirm your selection and enter the month setting mode S...

Страница 9: ...is case the unit can not be changed and the unit change setting step will be excluded Step 9 On pressing or the screen will display the On or OFF Press the S button to confirm the selection The meter...

Страница 10: ...e and is used to check that the meter and the test strips are working properly The test strip vials have CareSens Control Solution ranges printed on their labels Compare the result displayed on the me...

Страница 11: ...displayed on the screen Step 3 A test result will appear after the meter counts down from 5 to 1 After your control solution result appears on the display press for 3 seconds till the check icon appe...

Страница 12: ...e contact your authorized i SENS sales representative Caution To avoid infection when drawing a sample use a lancet only one time and Do not use a lancet that has been used by others Always use a new...

Страница 13: ...Sample Retrieval Step 4 Select a desired depth of one to five 1 5 on lance s adjustable tip Rotate ring to align desired number with arrow A beginning setting of three 3 is recommended Step 5 To cock...

Страница 14: ...meter s test strip port Push the strip in gently until the meter beeps Be careful not to bend the test strip The symbol will appear on the screen Step 7 If you want to attach an post meal flag to a t...

Страница 15: ...ically switch off after 3 seconds Discard used test strips safely in disposable containers Step 1 Unscrew general lancing device tip Step 2 Place protective cover on lancet Push the lancet ejector for...

Страница 16: ...observed during testing AlternativeSitesforTesting Things to know when using AST Please understand the following things before testing outside of the fingertip arms palms thighs and calves The capilla...

Страница 17: ...splayed even though you do not have hyperglycemia or hypoglycemia AST Precautions Do not ignore the symptoms of hyperglycemia or hypoglycemia When the results of the test do not reflect one s opinion...

Страница 18: ...the last 14 days ViewingTest Results Stored in the Meter s Memory Step 2 Press to view the average value and the number of tests performed before eating a meal for the last 14 days On pressing again t...

Страница 19: ...will be displayed The screen will then automatically change to the memory check mode At this time the bell icon indicating that the PP2 alarm has been set will be displayed on the screen Step 2 Setti...

Страница 20: ...ncel the alarm1 The OFF icon will blink on the screen Step 3 Press to adjust the time of the alarm1 A number representing the time will blink on the screen Press to set the time Press to end Setting t...

Страница 21: ...nto place Note Removing the meter batteries will not affect your stored result However you may need to reset your meter settings See pages 12 14 Caring for Your System Use a soft cloth or tissue to wi...

Страница 22: ...40 C 50 104 F and repeat the test after 30 minutes Understanding Error and Other Messages Note If the error messages persist contact your authorized i SENS sales representative Message What It Means...

Страница 23: ...r authorized i SENS sales representative Performance Characteristics The performance of CareSens N Blood Glucose Monitoring System Strips has been evaluated in laboratory and in clinical tests Accurac...

Страница 24: ...owsthattherecouldbevariationofupto4 2 Warranty Information Manufacturer sWarranty i SENS Inc warrants that the CareSens N Meter shall be free of defects in material and workmanship in normal use for a...

Отзывы: