I S TECHNOLOGY SOLUTIONS
8
the adapter, and the Downstream Brake Cylinder hose to the blanking plate.
11. Run the Daily Test on the application from the Main Menu and select 4P Adapter.
12.
When finished, remove the blanking plate from the 4 Pressure Adapter.
Attaching Air Hoses for the Single Car Test
To prepare for the 2 Pressure End-Of-Car Test:
1.
Connect the coalescing filter to the SUPPLY fitting on the Brake Pro™.
2.
Connect the shop air supply hose to the coalescing filter. Supply must be greater than the
Operating Pressure (> 95psi).
3. Connect the
BLACK
Brake Pipe hose to the Brake Pipe fitting on the Brake Pro™ and the
hose gladhand to the gladhand of the car to be tested.
4. Connect the
BLACK
Brake Cylinder hose to
GREEN
Brake Cylinder fitting on the Brake Pro™
and the other end to the pressure tap on the car to be tested. You will need to use the correct
fitting on the Downstream Brake Cylinder hose. The Brake Cylinder pressure tap must be
downstream of the Empty/Load Valve, if applicable.
5. Do NOT yet install the Dummy coupling on the gladhand at the other end of the car. You will
be instructed to do so by the application after starting the test and checking for Brake Pipe
blockage.
6. Run the Single Car Test on the application and select 2P EOC.
To prepare for the 4 Pressure End-Of-Car Test:
1.
Connect the coalescing filter to the SUPPLY fitting on the Brake Pro™.
2.
Connect the shop air supply hose to the coalescing filter. Supply must be greater than the
Operating Pressure (> 95psi).
3. Connect the
BLACK
Brake Pipe hose to the Brake Pipe fitting on the Brake Pro™ and the
hose gladhand to the gladhand of the car to be tested.
4. Connect the
BLUE
Auxiliary Reservoir Hose to the Auxiliary fitting on the Brake Pro™.
Connect the other end to the Auxiliary Quick Connect on the car.
5. Connect the
YELLOW
YELLOW
Emergency Reservoir Hose to the Emergency fitting on the Brake
Pro™. Connect the other end to the Emergency Quick Connect on the car.
6. Connect the
GREEN
Brake Cylinder Hose to the Brake Cylinder fitting on the Brake Pro™.
Connect the other end to the Brake Cylinder pressure tap on the car. This pressure tap must
be downstream of the Empty/Load Valve, if applicable.
7. Do NOT yet install the Dummy coupling on the gladhands at the other end of the car. You will
be instructed to do so by the application after starting the test and checking for Brake Pipe
blockage.